5
S-
Cape II MR Hand Control Operation Guide
OPTIONAL “J BOX” PROGRAMMING PROCEDURE
When programming the hand control,
unplug the adjustable bed electrical power
cord. Wait 30 seconds, then plug the cord
back in to the power source. This simple
process automatically sets the bed to the
program mode for 90 seconds. For
convenience, use this procedure in lieu of
pressing the
learn button
(located on the J
Box, mounted to the underside of the bed
base frame).
ALTERNATE
“
J BOX
”
PROGRAMMING
For adjustable beds equipped with “J box” only—no power down box.
At any point where “
press the learn
button
” is designated, disconnecting and
reconnecting the electrical power cord will
achieve the same function. Note that this
alternate programming feature is only
applicable to beds without a power down
box. Power down equipped adjustable
beds require use of the
learn button
when
programming the hand control.
POWERDOWN BOX OPERATION
In case of a power outage, press and hold
the
learn button
on the power down box
to lower the bed to the flat position
(
FIGURE 1
).
This function is only for lowering the bed
and will not operate the bed to any other
position. The (2) 9 volt batteries should be
replaced after this function is used.
In the event the powerdown feature does
not work, check to make sure the (2) 9 volt
batteries are good.
LEARN
BUTTON
FIGURE 1: Power down box learn button.
POWER
DOWN BOX
Summary of Contents for s-cape II MR