Revision 7
11
pipes must be flushed through so as to remove any debris & air locks.
WARNING! FAILURE TO CARRY THIS OUT MAY RESULT IN DAMAGE AND
FAILURE OF THE UNIT.
•
Make the water supply connection to the 15mm connection on the unit water
inlet stop tap on the PSH.
NOTE: If a sealing compound has been used on the supply feeds, ensure that it
is not overly applied as dislodged particles will cause a blockage that may
result in possible damage to the PSH water system.
•
For non-cold water outlet models
. Attach the flexible water hose (supplied)
to the ½” BSP basin water nozzle on the top of the basin, connect the other
end of flexible hose into the hand wash water outlet.
•
For models with the cold water outlet option
. The basin requires a potable
(drinking) cold water supply suitable for human consumption. It is the
responsibility of the installation contractor and end client to ensure the cold
water supply is suitable in all respects for human consumption. Attach the
flexible water hoses (supplied) into the water nozzle elbow push-fits on the top
of the basin. Connect other end of hoses as follows, viewed from the rear of
the basin: the LH basin nozzle hose to loop round & connect to the RH cabinet
push-fit elbow, the RH basin nozzle hose loops round & connects to the LH
cabinet push-fit elbow.
•
Waste connection.
The basin includes a waste outlet pipe tail connection of 1
½” (40mm) size. It should be terminated to a suitable deep seal waste trap
(not supplied) located 200mm (Min) below the centreline of the basin waste
pipe tail.
10.6 Electrical supply connection
NOTE! The electrical connections must be carried out by a qualified electrical
engineer in accordance with nationally approved IEE Regulations.
•
The unit will be supplied with a 1-metre flying lead for connection to the mains
‘switched fused spur’ supply.
•
Earth bonding should be carried out to comply with the Nationally Approved
Regulations. An earth lead is attached to a common earth plate on the basin
fascia, connecting relevant Water and Soap nozzles and Air grille, the free end
of the earth lead must be securely connected to the M6 equi-potential earth
connection point protruding from the bottom of the PSH control cabinet.
•
Control lead connection.
With the PSH Control cabinet there are 2 possible
Summary of Contents for PSH-20 Series
Page 1: ...Product Manual Model PSH 20 series Hand Wash Dryer ...
Page 2: ...Revision 7 2 Product Manual PSH 23 ...
Page 14: ...Revision 7 14 ...
Page 15: ...Revision 7 15 ...
Page 16: ...Revision 7 16 ...
Page 17: ...Revision 7 17 ...
Page 18: ...Revision 7 18 ...
Page 19: ...Revision 7 19 ...