background image

d)  Refit the electrical lead & plug to the trap heater element.

 

 

5.FOOT CONTROL PANEL OPTION 

a)  The following instructions apply to models FMA_22 & FMA_24 that have foot control push 

button operation. 

b)  Remove the button panel assembly from its mounting box by releasing the two countersunk 

screws one each end on the fascia panel. 

c)  The control box should be positioned into the aperture so that it is fitted flush with the 

finished surface of the wall. 

d)  Prior to fixing it, pass the flexible conduit from the handwash unit into the entry hole on the 

rear face of the box. Secure the box into position through the two fixing holes provided on its 
rear face. 

e)  To fit the button panel to its mounting box first connect the wiring plug to the plug on the 

flexible conduit from the handwash unit ensuring that the key on each plug is aligned. Place 
the panel then into its box avoiding the wiring becoming trapped or crushed and secure it 
with the two countersunk screws. 

f)  Replace the black plastic insulation cover remembering also to pass the soap tube through 

into the soap container storage area, and to reconnect the wiring to the soap prime switch if 
applicable. Fasten the cover to the cabinet with the four screws & washers retained 
previously. 

 

5.COMMISSIONING FOR USE 

a)  Open fully the mains water supply tap and the water inlet control valve on the unit. Check 

the system carefully for possible leaks. 

b) 

Switch “ON” the main electrical supply to the unit and then also on the unit itself at the 
switch located on the left side at the front of the cabinet.

 

DANGER!

 Components within the cabinet are now LIVE.

 

c)  Close the door panel and then refer to the USER & MAINTENANCE INSTRUCTIONS, 

SECTION 4 for instructions to set the water flow & temperature. 

d)  Refit the lower front cover to the unit ensuring that any wiring to it is reconnected to the main 

loom and secure with the six screws. 

e)  Refer to the user & maintenance instructions now to section 3 for commissioning of the soap 

system. 

f)  Check the operation of the warm air hand drier to ensure that it operates as outlined in 

section 2 of the USER & MAINTENANCE INSTRUCTIONS. Ensure that the dispensed air is 
warm. 

g)  Refer to the user & maintenance instructions section 2 for commissioning the 

decontamination heated waste trap function if fitted. 

h)  On completion of the units commissioning now hand over to the customer the following 

items:

 

  2 x Door keys, 

  1 x Product manual. 

6.TECHNICAL DATA

 

a)  Electrical supply: 

  220/230/240 AC 50Hz single phase. 

  Maximum rating: 220v-2650watts / 230v-2850watts / 240v-3100watts. 

WARNING: THIS APPLIANCE MUST BE EARTHED. 

b)  Water supply: 

  Thermal cut out 46ºC +/- 3ºC. 

  Temp of water at flow rates of 1.2 - 1.6 l/min 35ºC - 45ºC. 

  Nominal pressure range 1.75 - 10bar. 

 

Cold water feed ø15mm.

 

 

Summary of Contents for FMA 22

Page 1: ...cts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com PRODUCT MANUAL Handwash Drier MODELS FMA_22 24 25 26 ...

Page 2: ... suitable lintel should be provided e An electrical supply should be provided with a switched fused spur 13amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm The cable from the switch to the unit should be of minimum conductor size 1 5mm sq and should be fitted ready for connection to the Handwash unit f A mains cold wa...

Page 3: ...d two each side If a gap exists between the aperture sides and the cabinet then packing pieces should be inserted to prevent distorting the sides of the cabinet 3 ELECTRICAL CONNECTION WARNING This Appliance must be Earthed a The FMA Handwash unit is designed only for fixed wire type installation b The unit should be installed by a qualified electrician in accordance with the current Nationally Ap...

Page 4: ... a Open fully the mains water supply tap and the water inlet control valve on the unit Check the system carefully for possible leaks b Switch ON the main electrical supply to the unit and then also on the unit itself at the switch located on the left side at the front of the cabinet DANGER Components within the cabinet are now LIVE c Close the door panel and then refer to the USER MAINTENANCE INST...

Reviews: