d) Refit the electrical lead & plug to the trap heater element.
5.FOOT CONTROL PANEL OPTION
a) The following instructions apply to models FMA_22 & FMA_24 that have foot control push
button operation.
b) Remove the button panel assembly from its mounting box by releasing the two countersunk
screws one each end on the fascia panel.
c) The control box should be positioned into the aperture so that it is fitted flush with the
finished surface of the wall.
d) Prior to fixing it, pass the flexible conduit from the handwash unit into the entry hole on the
rear face of the box. Secure the box into position through the two fixing holes provided on its
rear face.
e) To fit the button panel to its mounting box first connect the wiring plug to the plug on the
flexible conduit from the handwash unit ensuring that the key on each plug is aligned. Place
the panel then into its box avoiding the wiring becoming trapped or crushed and secure it
with the two countersunk screws.
f) Replace the black plastic insulation cover remembering also to pass the soap tube through
into the soap container storage area, and to reconnect the wiring to the soap prime switch if
applicable. Fasten the cover to the cabinet with the four screws & washers retained
previously.
5.COMMISSIONING FOR USE
a) Open fully the mains water supply tap and the water inlet control valve on the unit. Check
the system carefully for possible leaks.
b)
Switch “ON” the main electrical supply to the unit and then also on the unit itself at the
switch located on the left side at the front of the cabinet.
DANGER!
Components within the cabinet are now LIVE.
c) Close the door panel and then refer to the USER & MAINTENANCE INSTRUCTIONS,
SECTION 4 for instructions to set the water flow & temperature.
d) Refit the lower front cover to the unit ensuring that any wiring to it is reconnected to the main
loom and secure with the six screws.
e) Refer to the user & maintenance instructions now to section 3 for commissioning of the soap
system.
f) Check the operation of the warm air hand drier to ensure that it operates as outlined in
section 2 of the USER & MAINTENANCE INSTRUCTIONS. Ensure that the dispensed air is
warm.
g) Refer to the user & maintenance instructions section 2 for commissioning the
decontamination heated waste trap function if fitted.
h) On completion of the units commissioning now hand over to the customer the following
items:
2 x Door keys,
1 x Product manual.
6.TECHNICAL DATA
a) Electrical supply:
220/230/240 AC 50Hz single phase.
Maximum rating: 220v-2650watts / 230v-2850watts / 240v-3100watts.
WARNING: THIS APPLIANCE MUST BE EARTHED.
b) Water supply:
Thermal cut out 46ºC +/- 3ºC.
Temp of water at flow rates of 1.2 - 1.6 l/min 35ºC - 45ºC.
Nominal pressure range 1.75 - 10bar.
Cold water feed ø15mm.