2.APPLIANCE PREPARATION & FITTING 

(a) Carefully remove the Handwash unit from its packaging and lay on the floor, flat on its back 

or stand vertically against the wall. 

(b) Using the keys provided open the top door panel. The door when fully open must be 

supported to prevent its weight straining against the side of the unit. Care must also be 
taken to prevent damage to the units fascia & stainless steel basin during the installation 
work. 

(c) Remove the internal black plastic insulation cover by releasing the four screw fasteners, two 

top and bottom. Safely retain these and the washers for refitting the cover later. Carefully 
ease out the cover from the Handwash unit and also pass the soap tube back through it into 
the cabinet. Note that on some models where a soap prime switch is fitted to the cover the 
cable to the switch must be unplugged from the unit before the cover can be fully removed. 

(d) Remove the lower front fascia panel by releasing the six screws (three each side). Unplug 

any wiring to the panel prior to finally lifting it away from the unit. Ensure that it is safely 
stored with its screws for refitting later. Close and lock the upper door panel. For units with 
foot panel operation ensure that the flexible conduit passing through the base of the unit is 
free. 

(e) Lift the unit towards the wall aperture and pass its flexible conduit through into the wall cavity 

first. Then fully insert the unit itself into the aperture ensuring that the fascia frame is flush 
tight against the wall surface. 

(f) To finally fix the unit into the aperture, holes may be drilled into the sides of the cabinet in 

both the upper and lower compartments. A minimum of four fixing points is recommended 
(two each side). If a gap exists between the aperture sides and the cabinet then packing 
pieces should be inserted to prevent distorting the sides of the cabinet. 

3.ELECTRICAL CONNECTION 

WARNING: This Appliance must be Earthed

 

a)  The FMA Handwash unit is designed only for fixed wire type installation. 
b)  The unit should be installed by a qualified electrician in accordance with the current 

Nationally Approved Regulations (IEE). 

c) 

Terminate the electrical supply into the terminal block positions “L E N” located on the left 
hand side of the cabinet and secure it into the cable clamp. 

d)  The cable must not come into contact with any other components or wiring within the unit, 

so as to prevent electromagnetic interference being passed into it. 

e)  Earth bonding should be carried out to comply with the Nationally Approved Regulations 

(IEE). Connections must be made to the following points: 

  Water supply pipe, * Sink waste outlet & sterilizer trap if fitted, 

 

Equipotential earth point for cross bonding multiple units together.

 

 

4.WATER SUPPLY & WASTE CONNECTION 

IMPORTANT!

 For installations liable to freezing conditions, frost protection and lagging must be 

provided. 

a)  Prior to final connection of the water supply to the unit the pipes must be flushed through so 

as to remove any debris and air locks. Failure to carry this out may result in damage & 
malfunction of the unit. 

b)  Complete the water supply connection to the units control tap located below the basin on the 

rear left side, taking care that any sealing compounds used are not excessively applied 
which may cause a blockage. 

c)  Final connection between the waste trap supplied with the unit and the main waste pipe can 

now be complete

d with 1¼” size PVC pipe. If the unit is supplied with a decontamination 

heated waste trap, then copper pipe of 35mm O/D is required to fit to the outlet joint. PVC 
pipes may be coupled to the copper tube if required. 

Summary of Contents for FMA 22

Page 1: ...cts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com PRODUCT MANUAL Handwash Drier MODELS FMA_22 24 25 26 ...

Page 2: ... suitable lintel should be provided e An electrical supply should be provided with a switched fused spur 13amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm The cable from the switch to the unit should be of minimum conductor size 1 5mm sq and should be fitted ready for connection to the Handwash unit f A mains cold wa...

Page 3: ...d two each side If a gap exists between the aperture sides and the cabinet then packing pieces should be inserted to prevent distorting the sides of the cabinet 3 ELECTRICAL CONNECTION WARNING This Appliance must be Earthed a The FMA Handwash unit is designed only for fixed wire type installation b The unit should be installed by a qualified electrician in accordance with the current Nationally Ap...

Page 4: ... a Open fully the mains water supply tap and the water inlet control valve on the unit Check the system carefully for possible leaks b Switch ON the main electrical supply to the unit and then also on the unit itself at the switch located on the left side at the front of the cabinet DANGER Components within the cabinet are now LIVE c Close the door panel and then refer to the USER MAINTENANCE INST...

Reviews: