background image

Note that another cycle shall not start unless your hands or any other item in the sensor 
detection zone/range is removed momentarily. 

 

Time Cycle Adjustments. 

 

To adjust the time cycle settings for water and air dispensing, access must be made into the 
cabinet behind the unit upper fascia panel, the security key provided is used to remove the 
two  screws  securing  the  panel.  An  internal  cover  plate  is  mounted  behind  the  upper  front 
fascia 

panel. 

It 

is 

recommended 

that 

only 

qualified 

personnel 

carry 

out 

inspection/adjustments  due  to  the  risk  of  electric 
shock  if  the  appropriate  precautions  are  not 
taken.  Switch  OFF  the  electrical  supply  at  the 
fused spur or mains switch board. 

 

To the left of the internal cover plate, switch OFF 
the  “Electrical  Isolator”  to  ensure  the  electrical 
supply to the unit remains disconnected. Remove 
the  inner  cover  plate  by  releasing  the  screws 
securing it and then ease it out from the unit.  
The  handwash  will  be  fitted  with  one  of  two 
electronic controllers, (TCU041 or TCU100) which 
is  mounted  towards  the  top  inside  face  of  the 
handwash  housing.  The  TCU041  controller  is 
used  on  units  with  just  soap,  water  and  air 
functions,  push  button  operated.  The  time 
settings  may  be  adjusted  by  following  the 
adjacent instructions. The TCU100 is fitted to the 
CME_45s model, time cycles may be adjusted using the onboard ‘Control Interface module’. 
For further details contact Wallgate.  

 

After all adjustments are completed ensure that the internal cover plate is correctly replaced 
& that the switch Electrical Isolator is in the ON position (Red light illuminated).  Close & lock 
the door panel. 

 

3. REPLENISHING THE SOAP 

(a) Using the castellated keys provided, open the top door and remove the empty soap 

container. Place the soap tubing into the new container of soap ensuring it reaches to the 
bottom. Position the container into its compartment. The soap recommended for use in 
the unit is a free flowing liquid soap. It is particularly important that the unit is not filled with 
creams or gel soaps, which will not dispense properly or may even, cause a blockage. A 
range of recommended soaps and their specification are available direct from Wallgate or 
your supplier. 

(b) To prime the soap press the soap push button several times until soap begins to 

consistently dispense from the nozzle. Close & lock the hand wash door. 

(c) Soap levels should be checked periodically to maintain efficient operation of the unit. 

 

4. ADJUSTING THE WATER TEMPERATURE 

(a) Access is required to the inside of the cabinet so the 

electrical supply must be 

switched OFF

 before proceeding any further. 

(b) Using the castellated key provided, open the top door & then remove the internal cover & 

the soap container. The water flow control tap is located to the left of centre at the back of 
the cabinet. To increase the temperature of the water turn the tap clockwise and to 
decrease the temperature, turn it anti-clockwise. Make small adjustments and then 
activate the unit to check the effect. The unit is fitted with a safety flow switch, which will 
only operate the water heater when the flow rate is set above 1.2 litres/minute, (Typical 
set rate 1.6ltr/min). Replace the internal cover & soap container & close and lock the door 

 

Summary of Contents for CME 41s

Page 1: ...ntact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com PRODUCT MANUAL Handwash Drier Models CME_41s 45s CME_41s CME_45s ...

Page 2: ...ture then a suitable lintel must be installed c Complete all surface finishes i e screed plaster or tiling to the wall before fixing the mounting brackets as these must be fitted flush with the finished surface d An electrical supply 230v 50Hz should be provided e to the handwash unit water inlet may be made to the supplied tap on the unit If the unit is to be connected to a gravity tank fed suppl...

Page 3: ...utlet Equipotential earth connection for bonding together multiple units installed connection positioned on back of cabinet below sink 5 WATER SUPPLY WASTE CONNECTION IMPORTANT For installations liable to freezing conditions frost protection pipe insulation must be fitted a Prior to final connection of the water supply to the unit the pipes must be flushed through so as to remove any debris air lo...

Page 4: ...s section 3 Close lock the door f Check now that a full cycle operates correctly as detailed in section 2 of the User Maintenance Instructions g On completion of the above the following items should be passed to the customer 2 x door panel keys this manual 7 TECHNICAL DATA a Electrical supply 230v ac 50Hz single phase Maximum rating 230v 3000watts WARNING THIS APPLIANCE MUST BE EARTHED b Water sup...

Page 5: ......

Page 6: ...ed model follow the instructions below For soap dispensing press the hand or foot button marked SOAP Dosage depends entirely on the number of times the button is pressed The electric type pump runs for a pre set time 0 3 seconds to deliver approximately 5ml of soap This can only be adjusted by consulting the manufacturer The soap button however can be pressed several times for repeat operations if...

Page 7: ...d that the switch Electrical Isolator is in the ON position Red light illuminated Close lock the door panel 3 REPLENISHING THE SOAP a Using the castellated keys provided open the top door and remove the empty soap container Place the soap tubing into the new container of soap ensuring it reaches to the bottom Position the container into its compartment The soap recommended for use in the unit is a...

Page 8: ...iling Proprietary de scaling agents may be used to remove lime scale from the bowl waste trim and the water nozzle c From a users point of view the most important care items are Clean the water spray periodically to remove lime scale Clean the soap dispensing nozzle and occasionally wash the soap system through with warm water Check the soap level regularly only use recommended soaps Have the moto...

Reviews: