(e) Place a full soap container (2.5ltr) into the right hand compartment of the top internal
cover. Place the tube into the bottle ensuring it reaches to the bottom & then fit the plastic
bung into the bottle neck. Switch ON the electric supply & prime the soap system by
pressing the priming pad/button in the soap container compartment of model 45s, or front
fascia ‘SOAP’ button on model 41s until the soap is dispensed, (as detailed in “User &
Maintenance Instructions” section 3). Close & lock the door.
(f) Check now that a full cycle operates correctly as detailed in section 2 of the “User &
Maintenance Instructions”.
(g) On completion of the above, the following items should be passed to the customer: 2 x
door panel keys & this manual.
7. TECHNICAL DATA.
(a) Electrical supply:
230v ac 50Hz single phase.
Maximum rating: 230v – 3000watts.
WARNING THIS APPLIANCE MUST BE EARTHED.
(b) Water supply:
Thermal cut out 45
°
C (+/- 3).
Temp of water for flow rates 1.2 – 1.6 l/min, 35
°
C - 45
°
C. (Typically with ambient @ 10
- 20
°
C).
Nominal pressure range, 1.75 – 10bar.
Cold water feed
∅
15mm copper.
(c) Waste,
∅
1 ¼” (32mm) pipe (internal), connection to 1 ¼” elbow (compression) on 1 ¼”
BSP sink waste.
Summary of Contents for CME 41s