2.1   Safety instructions

Improper use and non-compliance with the operating 
manual may jeopardize:

•  your life

•  your health

•  charging system and vehicle.

Safety devices on the charging system

•  must not be removed,

•  must not be manipulated,

•  must not be bypassed,

•  before each use, it must be checked that the equip-

ment (e.g. housing, connecting line, charging coupler) 
is undamaged,

•  must be repaired or replaced as necessary, in order 

to preserve the functional properties.

Ensure that:

•  safety identifications, e.g. yellow-colored marks,

•  danger signs and

•  safety lights

remain easily visible and retain their effectiveness.

•  When operating the charging system, do not use 

any extension cables, cable reels, multisocket power 
strips, or travel adapters.

•  Do not insert any objects into the charging coupler of 

the charging system.

•  Protect the socket-outlets and plug-in connections 

against moisture and water or other liquids.

•  Never immerse the charging system or the charging 

coupler in water or other liquids.

•  Do not disconnect the charging coupler from th ve-

hicle during charging.

wallbe® takes responsibility only of the charging sys-
tem in its delivered condition and for any work perfor-
med by skilled wallbe® personnel.

Notes for people with a pacemaker (PM) or implanta-
ble cardioverter defibrillator (ICD)

Charging systems from wallbe® that are operated as 
intended, comply with the European guideline on elec-
tromagnetic compatibility regarding radiated interfe-
rence.

Should people with a pacemaker (PM) or implantable 
cardioverter defibrillator (ICD) wish to conduct activities 
on charging systems and their devices in the inten-
ded manner, wallbe® is not in a position to make any 
statement regarding the suitability of such medial de-
vices. wallbe® is not able to assess the pacemakers or 
concerned implantable cardioverter defibrillators with 
regard to their susceptibility to electromagnetic radia-
tion. This is something that only the manufacturers of 
the pacemaker or implantable cardioverter defibrillator 
can do.

wallbe® therefore recommends only allowing the peo-
ple in question to work on its charging systems after 
consultation with the manufacturer of the pacemaker/
defibrillator and the relevant insurance company. En-
sure at all times that no health or safety risks are in-
volved.

Note

: People with a pacemaker or defibrillator may not 

work on or stand near the charging systems and their 
devices, e.g. to perform maintenance operations or 
rectify any faults.

Working on the charging system without risk

Before plugging the charging coupler into the vehicle

•  The connecting line of the charging system must be 

completely unwound.

•  Check whether the housing of the charging system, 

the connecting line, the charging coupler, and the 
connectors are undamaged.

•  Take hold of the plug-in connection of the charging 

system only on the charging coupler and not on the 
charging cable.

•  Ensure that no-one can trip e.g. over the charging 

cable.

During the charging process

•  Keep unauthorized persons away from the charging 

system.

•  When the charging system is connected, you must 

Summary of Contents for LEO

Page 1: ...Driving eMobility wallbe Charging station LEO Wallbox INSTALLATION MANUAL 211510 a 09 2020...

Page 2: ...Safety 4 2 1 Safety instructions 4 2 2 Installation and tests 5 2 3 Protective devices 7 2 4 Operator control elements 7 3 Installation 8 3 1 Prerequisites 8 3 2 Scope of supply Enclosed accessories...

Page 3: ...te control system The char ging system is intended exclusively for stationary ins tallation The charging system may only be operated and used by persons who have read the operating manual The electric...

Page 4: ...compatibility regarding radiated interfe rence Should people with a pacemaker PM or implantable cardioverter defibrillator ICD wish to conduct activities on charging systems and their devices in the...

Page 5: ...he charging system is equipped with integrated AC residual current detection as a convenience function This residual current detection switches off the char ging system at the latest if there is a res...

Page 6: ...vehicle simulation in accordance with EN 61581 1 The measurements must be carried out with the adapter in the C mode Carry out the mea surements on the measuring sockets of the test adap ter with a su...

Page 7: ...tion 2 Nameplate The charging system can be operated with a single button LED combination Fig 2 An optional external blocking device e g key switch can be connected to the internal interface Functions...

Page 8: ...ed by hail or similar Do not expose the Wallbox to direct sunlight because this can cause it to overheat The individual phases of the supply voltage must each be protected with residual current device...

Page 9: ...and prepare the mounting holes according to the type of mounting surface e g dowels for masonry The screw diameter must not exceed 8 mm 3 Screw in the two top fastening screws Note The fastening scre...

Page 10: ...e connecting line into the cable gland 7 Tighten the cap nuts of the cable gland approx 4 Nm Figure 7 Terminal clamps of the power supply unit Caution Heed the terminal sequence When clamping the conn...

Page 11: ...luded in the enclosed accessories 3 6 Commissioning 1 2 Figure 10 wallbe LEO 1 Pushbutton LED combination 2 Nameplate 1 Provide power to the Wallbox Once the Wallbox is connected to the mains the LED...

Page 12: ...djustable from 6 A to 16 A in 2 A increments Nominal frequency 50 Hz Connection method Spring clip method Charging connection coupler Type 2 Length of charging cable 5 m Operation status infor mation...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...s reserved This document may not be copied in whole or in part or reproduced in any form or form without the written permission of wallbe GmbH All illustrations in this manual are only examples and ma...

Reviews: