Petring Energietechnik GmbH – Paderborner Str. 76 – 33189 Schlangen
Tel: +49 5252 989440 Mail: [email protected]
22
4.0 Technical details: wallb-e eco 2.0
Our wallb-e eco 2.0 - 3.7kW was especially developed for private use, thus our wallb-e eco
2.0 offers unmatched usability and comfort combined with secure charging according to IEC
61851 Mode 3.
Our wallb-e eco 2.0 comes with an attached cable, which if not used, can be parked inside a
parking socket and is always in reach and ready to charge.
Technical details
Model
wallb-e eco 2.0
3,7kW
wallb-e eco 2.0
4,6kW
wallb-e eco 2.0
7,4kW
wallb-e eco 2.0
11kW
wallb-e eco 2.0
22kW
Dimensions in
mm
170x250x130
170x250x130
170x250x130
170x250x130
170x250x130
Weight
Ca. 3kg*
*(Depends on
cable/version)
Ca. 3kg*
*(Depends on
cable/version)
Ca. 3kg*
*(Depends on
cable/version)
Ca. 4kg*
*(Depends on
cable/version)
Ca. 4kg*
*(Depends on
cable/version)
Temp. rating
-20 to +55°C
-20 to +55°C
-20 to +55°C
-20 to +55°C
-20 to +55°C
IP-Class
IP65
IP65
IP65
IP65
IP65
Charging cable
230V/1P/20A
Type 2 or Type 1
Or
Type 2 socket
230V/1P/20A
Type 2 or Type 1
Or
Type 2 socket
230V/1P/32A
Type 2 or Type 1
Or
Type 2 socket
400V/3P/20A
Type 2
Or
Type 2 socket
400V/3P/32A
Type 2
Compliance
Mode 3
IEC61851
Mode 3
IEC61851
Mode 3
IEC61851
Mode 3
IEC61851
Mode 3
IEC61851
Load contactor
2pol. 25A
2pol. 25A
2pol.40A
4pol. 25A
4pol. 40A
Control fuse
1pol.B6
1pol.B6
1pol.B6
1pol.B6
1pol.B6
RCD
Fi Typ A
0,03A/25A
Fi Typ A
0,03A/25A
Fi Typ A
0,03A/40A
(Not integrated
in the Type 2
socket version!)
Not integrated
Nicht integrated
LS-switch
Not integrated
Not integrated
Not integrated
Not integrated
Not integrated
Authorisation
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External approval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External approval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External approval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External approval
Standard:
ON/OFF Button
Optional:
Keyswitch
RFID
External approval
Case lockable
No
No
No
No
No
Energymeter
No
No
No
No
No
Protocols
Modbus
Modbus
Modbus
Modbus
Modbus
Interfaces
RS485
Opt. RJ45
RS485
Opt. RJ45
RJ45
RJ45
RJ45
Error-report
Error-LED
Error-LED
Error-LED
Error-LED
Error-LED