min. 300 mm
min. 300 mm
min. 400 mm
F
U
E
L
1030
4320
1028
Ø 43 mm
62 mm
Installation
en
Location under a window
The exhaust head
4300
shall not be installed under an
opening
window or closer
than 300 mm to the window’s edges. If the exhaust head has to be installed near
an opening window, the window must be prevented from opening or fitted with a
switch that prevents the hob from being used when the window is open.
Installing the hoses
Installation
When you have chosen the location for the
4300
exhaust head, you should find the
best place to lead the combustion gas and intake air hoses through the bottom of
the vehicle.
Drill two holes of approximately Ø 43 mm for the hoses, as illustrated. The holes
must be 62 mm apart. Install the
4320
bottom penetration cover plate set. Insulate
the combustion gas pipe with the
1030
fibreglass sleeve. If the floor structure of
the vehicle at the location of the combustion gas hose is not heat resistant, remove
part of the insulation and replace it with heat-resistant material.
Vehicle floor structure
D10341D
- 57 -
XC Duo
490541G