background image

SUN SWITCH 

(IN PI THERMO MODE)

Orange thermostat light will begin to
flash every 30 seconds. 

Sun Switch automatically turns the heater off if the
temperature r3 C (37 F) above the set level for 
1/2 hour due to temperature increase in weather. 

Rotate the 

Temperature/Power Knob

slightly to turn the Sun Switch off
temporarily. 

If heating is still needed, turn the device
back on manually.

Red combustion light will begin to
flash for about 5 minutes, while
the heater is cooling down. 

SHUTDOWN

Press the 

Heat Button 

down for 2 seconds.

Yellow heating light will shut off
immediately.

Heater cannot be restarted until the cool down has
completed. The heating mode that was used last upon
shutdown will be the same mode when the heater is
turned on again. 

see 

ignition 

 

Reach Out to a Professional for the Following: 

Glow Failure

Combustion Air Blower Fault

Main Blower Fault

2 s

2 s

2 s

2 s

2 s

Set temperature is higher than the 

cabin temperature - power is increasing
Set temperature is lower than the cabin

temperature - power is decreasing

30 s

30 s

Heating on

Combustion has begun/is running

Low voltage (usually about 15 sec

after initiating start) 

Ventilation on

Sun Switch has shut down the device

Cooldown/Flameout

Overheat

Locked for security

The device locks itself 

after two unsuccessful starts. 

Reminder indicating there was a fault

after fault code flashed for 5 min 

Air Boost on

30 s

30 s

10 s

10 s

In Remote Control Mode

HEATER LIGHTS

See instructional video

to unlock 

If the unit has locked itself,
all three lights at the top of
the panel will flash,
signaling there has been a
failure that should be
investigated and resolved
prior to further use. Lights
will flash for about 5 min.

1) While the lights are still
flashing, switch the main
power off from the battery
(Pull power plug, remove
the fuse, open breakers, or
in-line switch). 

2) Wait for 5 sec. and
switch the main power
back on.

3) Press Heat Button (3) for
more than 3 seconds to
shut down the heater.

4) Restart the heater
normally. 
 

UNLOCKING THE

UNIT 

GB heaters can be controlled remotely with a Wallas
Remote Control 4430 accessory, which is available for
purchase separately. Remote Control deactivates the Sun
Switch. Not available in the US.

REMOTE CONTROL

Reviews: