Air boost
The air boost is meant to be used when you need bigger air volume for example to
remove moisture. This function forces the main blower run with maximum effect
When the heater is running, the air boost can be activated by pressing the ventila-
tion switch (7) one time shortly (less than 2 seconds). The heating stays on adjust-
ed value but ventilation is boosted to maximum effect. The air boost is indicated by
the green ventilation light (8). When you press the switch second time shortly, the
air volume goes to maximum. Third press restores the air volume and the green
indication light (8) shuts off.
Ventilation
Fresh air ventilation activates by pressing the ventilation switch (7) continuously at
least 2 seconds. Ventilation is indicated with the green ventilation light (8). Venti-
lation is deactivated by pressing the ventilation switch (7) continuously at least 2
seconds. The green ventilation light (8) will shut off.
When pressing the ventilation switch (7) continuously at least 2 seconds, while
heating is on, the heater will shut off and after the aftercooling mode, the heater
goes to ventilation mode.
Ventilation is 2-positions (Min-Max). The thermostat control deactivates after
adjusting the ventilation effect. When pressing the heating switch (3) at least 2 sec-
onds while the ventilation is on, the heater will start and go to heating mode.
Shutdown
You can shut down the heater by pressing the heating switch (3) in continuously
for at least 2 seconds. The yellow heating indicator light (9) will go out immediately.
The red combustion indicator light (1) will continue to blink for ca. 10 minutes, while
the device is cooling down. You cannot restart the device until the combustion light
has stopped blinking.
Remote control
The heater can be controlled manually with an accessory, which can be purchased
separately.
If the device is started using the remote control, the orange indicator light (5) on the
control panel will blink at 10-second intervals.
The sun-switch is not enabled in this mode.
The ventilation cannot be used with the remote controller.
The unit doesn’t start before the after cooling phase is finished.