background image

G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 1 

 

 
 
 

MULTISAN

PRO

 

Automatic toilet and waste water collection tank and electrically operated macerator pump system. 

 

INSTALLATION AND SERVICING INSTRUCTION MANUAL

 

PLEASE READ ALL INSTRUCTIONS PRIOR TO PROCEEDING WITH ANY WORK 

A permit may be required. Check with the plumbing, drainage and/or electrical inspectors before installation.  

Local regulations may stipulate additional installation requirements.  

You must consult with your local plumbing and drainage inspector for a permit approval. 

 

AFTER INSTALLATION, THE INSTALLER MUST HAND THIS MANUAL TO THE OWNER  

FOR THE PROPER OPERATION AND MAINTENANCE OF THE MULTI-SAN 

Failure to do so will result in the installer being made liable under the current legislation for any future claims 

resulting from any incorrect operation or servicing.  

 

Congratulations on your purchase of Multisan-Pro wastewater package pump. For this product to meet its 

expected lifetime please ensure it is installed by a qualified technician and follow the maintenance 

schedule as detailed in section 13.2. Please keep a record of by whom and when the maintenance was 

completed, that need to be provided to us when asked for. 

 

 
 

 

 
PAGE INDEX 

Section 
1. General view and connections  ................. 3 
2. Waste water connections/ Shower/Bath..... 3 
3. Product overview  ..................................... 5 
4. Applications  ............................................. 5 
5. Features & benefits  .................................. 6 
6. Pump hydraulic capability............................6 
7. Warning: for your safety  .......................... 7 
8. List of fittings supplied & extra may require.7 
 

Section  
9.  Alarm & solenoid valve system….. 

 7/8 

10. General installation aspects & electrical data.9 
11. Pump Operational Logic...............................10 
12. Specific Installation (High Temp/remote).10/11 
13. Care and servicing……….............................11 
14. Warranty & Limitations……………………….12 
15. Fault Finding chart ...................................12/14 
16 Spare parts drawing & list..........................15/19 
 

Limitations:  We reserve the right to change these instructions and improve the product without prior notice. 

 

  AUCKLAND 

   WELLINGTON 

  CHRISTCHURCH 

  

 

 

55 MAURICE RD, PENROSE 

 

 

 

 

 

35 BUCHAN ST 

  PO 

BOX 

12 

387 

      SYDENHAM 

 

 

PH     09   622 9100 

 

 

PH 027 543 8634 

 

 

PH     03   365 6453 

 

 

FAX   09   622 9119 

 

 

 

 

 

 

FAX   03   366 6995 

 
 
 

Summary of Contents for MULTISAN PRO

Page 1: ...ge pump For this product to meet its expected lifetime please ensure it is installed by a qualified technician and follow the maintenance schedule as detailed in section 13 2 Please keep a record of b...

Page 2: ...mp and motor unit Toilet pan connection Gas and watertight collection tank Pump cover Manual Run Reset Button Tank Vent provided with Carbon Use this port in case need to vent outside via vent pipe Do...

Page 3: ...olate the pipe from the building structure to prevent vibration or noise transmission during operation Any horizontal section of the delivery pipework should always have a continuous rise towards the...

Page 4: ...nic products such as condoms sanitary pads wet wipes tampons nappies sand stones tar cement coarse paper non water soluble paper towels cardboard plastic bags fat oil etc in the toilet to be affixed t...

Page 5: ...al limitations or because there was no unit available with adequate performance The MULTISAN PRO has been developed to overcome these problems including Below sewer line installations Where gravity fa...

Page 6: ...able check your installation requirements against the dimensions and hydraulic capabilities of the unit This graph is based on a flow of 35 litres min If flows exceed 35 L min please contact Wallace P...

Page 7: ...pigot connecting to pump other end socket to connect waste pipe from WHB Sink or any other domestic appliance and to connect 40mm DWV pipe as vent connection if required as per local rules and regulat...

Page 8: ...r bigger cable Check with Wallace Earth wire to be connected to Earth terminal E as shown Volts Free Contacts in the circuit board which activates in case of Alarm Connect Volts Free Terminal No 1 com...

Page 9: ...transmission 3 Install only the supplied full flow non clog swing check within one metre of the pump in a vertical position below and close to the supplied isolating ball valve 5 All pumped appliance...

Page 10: ...evel difference between WC pan and pump unit should NOT BE MORE THAN 900mm Suitable access must be provided for operation maintenance and repairs of the unit at all times An adequate overflow outlet m...

Page 11: ...between services should be 6 months for heavy usage unit and 1 year for light to medium usage unit c All Alarm activation occurred to be noted as to when date time and how and who rectified it and wha...

Page 12: ...quid Level switch operated by water level remains in the ON position because a pipework is blocked or b pump is blocked or c tank is blocked or d delivery hose is kinked e pressure switch is water log...

Page 13: ...t intervals without any liquid discharged into the collection tank Water is leaking back flowing into the unit from the delivery pipe triggering the motor to re start Non return valve does not close p...

Page 14: ...nk chamber under the cover Power is off Overload trip Inflows exceeding pump capacity Blockage in the pipework Shower pipe also has other pipes connected to it Pump malfunctioning Overflow pipe if app...

Page 15: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 15 16 Spare Parts drawing list pump unit...

Page 16: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 16 Complete lifting unit...

Page 17: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 17 Circuit board...

Page 18: ...hose MICROBOY 117604 1 330 2 Hose clip 20 32 117033 1 340 2 O ring 34 52x3 53 117034 1 350 4 Rubber foot 117035 1 360 2 Countersunk 3 5x9 5 117605 1 370 1 Non return valve valve 117056 1 410 1 Lense h...

Page 19: ...m flange MICROBOY E2 117002 1 2 280 1 O ring 120x2 5 117007 2 290 4 Lens head screw 4 2x19 270024 2 300 1 O ring 72x3 5 117700 2 310 1 Cutting plate 117198 2 320 3 Countersunk M4x8 117199 2 330 1 Hose...