background image

START UP

CHARGING

IMPORTANT: Charge the Walker Alarm at least  

6 hours; but not more than 24 hours. 

➊  

Turn switch to 

OFF

 position 

➋  

Plug in charging cable to the wall outlet and plug charging 
cable into the side charging port on the  
Walker Alarm. 

YELLOW LED

 lights during charging. 

GREEN LED

 indicates a full charge.

The battery manufacturer recommends not to leave 

the battery in a charge function over 24 hours.

LOW BATTERY INDICATION

After 8 hours or more of continuous normal use the 

YELLOW

 

Low Battery Light will start to flash indicating 10-15 left of 
battery charge left. After the remaining 10-15 minutes is up, 
the Walker Alarm will 

CHIRP

 and flash 

YELLOW

 for about 2 

seconds and then shut off.

Note: Please read the information on lithium polymer batteries on page 10.

CHARGING 

CABLE

ON/OFF

SWITCH

2

Summary of Contents for 4200-100

Page 1: ...A PRODUCT Model 4200 100 A Computer Based DME Device Follow this instruction manual to ensure safe use of the Walker Alarm Device Instruction Manual for Rehabilitation Facilities...

Page 2: ...full charge The battery manufacturer recommends not to leave the battery in a charge function over 24 hours LOW BATTERY INDICATION After 8 hours or more of continuous normal use the YELLOW Low Battery...

Page 3: ...of the Dip switches move a switch up or down with a tip of a ball point pen feel when the switch engages into the up or down position 1 Vibrate On Off 2 Beep Alarm On Off 3 Color Glow On Off 4 Distan...

Page 4: ...Sound Control The ON position activates the BEEP audio alarm feature SWITCH 3 Light Control The ON position activates the LED light visual feature that flashes WHITE then RED or Glows GREEN 1 Up Down...

Page 5: ...8 Switch 5 DOWN Switch 6 DOWN 1 Up Down 22 Distance Alarm 2 3 4 5 6 7 8 Switch 4 DOWN Switch 5 DOWN Switch 6 DOWN E DIP SWITCH SETTINGS Distance Alarm P Switch 5 UP Switch 6 DOWN 2 3 4 5 6 7 8 1 Up Do...

Page 6: ...DOWN 1 0 Distance Alarm 2 3 4 5 6 7 8 UP Switch 5 DOWN Switch 6 DOWN 1 Up Down 22 Distance Alarm 2 3 4 5 6 7 8 Switch 4 DOWN Switch 5 DOWN Switch 6 DOWN ANCE DIP SWITCH SETTINGS 6 Distance Alarm 4 UP...

Page 7: ...peat until the patient moves back into the Safe Green Zone SAFE ZONE Walk with the walker keeping the Green LED light on THIS IS YOUR TARGET STAY IN THE GREEN SAFE ZONE 16 OR GREATER DISTANCE ALARM ZO...

Page 8: ...ng training patient in the use of the walker Follow this suggested procedure or similar for all types of walkers If the patient has previous training in the use of the walker do an proficiency assessm...

Page 9: ...ide bar mount that is installed on the walker you intend to use The sensors must be facing the patient Turn on the Walker Alarm using the ON OFF switch on the side of the device 28 GREEN Glow Safe Zon...

Page 10: ...dule that protects the battery pack from over charging and over discharging reducing the risk of explosion fire and damage CHARGER AND CHARGING All Walker Alarms will be supplied with UL approved char...

Page 11: ...RNING This is a COMPUTER BASED ELECTRONIC DEVICE Keep away from Water DO NOT DROP OR JOLT Operating Temperature 0 70 C 32 158 F Always follow Walker Alarm instructions for operation SAFETY DEVICE REME...

Page 12: ...ements PRIMARY BENEFITS May reduce the risk of falling Will assist with Walker Physical Therapy Training Sessions by having a Green Zone SAFE ZONE box to be seen by person in therapy balance posture a...

Reviews: