62
Maintenance Instructions
S18
Checking and Servicing
CHECKING/SERVICING
DANGER
To prevent accidental starting of the en gine
when servicing or adjusting the ma chine,
remove the key from the ignition switch
and disconnect the spark plug wires.
Security of Air Filtration Components
NOTE:
The following inspection is
only an exter-
nal inspection
and should be done without
“dis-
turbing”
the filtration components.
On a daily basis, visually inspect the external
condi tion of the complete air cleaner system. The
follow ing items should be inspected:
1. Check the Cummins/Fleetguard OptiAir™ air
cleaner canister for damage. Make sure the
cover is in place and the cover latch is se-
cure—do not run the engine without the air
cleaner cover in place and secure.
2. Inspect the air intake hose for cracks, nicks,
cuts, etc., and check the hose clamps for
tight ness.
Battery
IMPORTANT:
Make sure battery is securely
mount ed in the frame. A loose battery may cause
damage to the case resulting in acid leakage and
severe dam age to the machine. A hazard may be
created by damage to critical working parts and
safety systems.
The battery comes sealed and is maintenance-
free, so the electrolyte level will not need to be
checked or filled.
CAUTION
Important Battery Service, Installation, and
Charging Tips:
●
Do not allow the battery cables to touch
opposing terminals. When connecting
battery cables attach the positive (+)
cable to positive (+) battery terminal
first, followed by negative (-) cable to
negative (-) battery terminal.
●
Never start the engine when the cables
are loose or poorly connected to the
battery terminals.
●
Never disconnect battery while engine
is running.
●
Never use a quick battery charger to
start the engine.
Cleaning the Terminals
If battery terminals are corroded,
remove the
battery
from the mower. Using a wire brush,
remove corro sion with a solution of
one part bak-
ing soda and four parts water.
Rinse with clean
water. Coat the terminals with petroleum jelly or
terminal protector spray to retard further corrosion.