Installation
13
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1.
Waldorf Target Tops do not require an electrical connection, as they function totally on gas supply
only.
2.
It is essential that gas supply is correct for target top to be installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a. Gas Type the appliance has been supplied for is shown on coloured sticker located above gas
connection and on the rating plate. Check this is correct for gas supply appliance is being
installed for. Gas conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in ‘Specifications’ section of this manual.
Check gas supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is shown on Rating Plate and in ‘Specifications’ section of this
manual. Input rate should be checked against available gas supply line capacity. Particular
note should be taken if target top is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance
with as few tees and elbows as possible to give maximum supply volume.
3.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and
it is NOT to be adjusted.
Regulator connections are
3
/
4
" BSP female.
Connection to appliance is
3
/
4
" BSP male.
(Refer to ‘Specifications’ section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
4.
Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
unit is level and at correct height.
5.
Connect gas supply to appliance. A suitable jointing compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.