5
Installation Requirements
NOTE:
•
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local electrical, gas, health and safety
requirements.
•
This appliance shall be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Waldorf Griddle Toasters are designed to provide years of satisfactory service and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia
:
- AS5601
- Gas Installations.
New Zealand:
- NZS5261
- Gas Installation.
United Kingdom:
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- Installation of Catering Appliances.
- BS5440
- 1 & 2 Installation Flueing & Ventilation.
Ireland:
- IS 820
- Non Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to relevant codes and manufacturers specifications shown in this section will void
the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer, are only
allowed to be adjusted by a qualified service person. They are not to be adjusted by the
installation person.
Unpacking
•
Remove all packaging and transit protection from the appliance including all protective plastic
coating from the exterior stainless steel panels.
•
Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
•
Report any deficiencies to the distributor who supplied the appliance.
•
Check that the available gas supply is correct to that shown on the rating plate located on the right
hand inner side panel.
•
Check that the following parts have been supplied with the appliance:
Enamelled Crumb Tray
1
Toasting Rack
1
Toasting Rack Tray (St/Steel)
1
Grease Drawer
1
Adjustable Legs
4
Gas Regulator
1
Alternate Gas Conversion Kit
1
Location
1.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3.
Position the appliance in its approximate working position.
4.
All air for burner combustion is supplied from underneath the appliance. The legs must always be
fitted and no obstructions placed on the underside or around the base of the appliance, as
obstructions will cause incorrect operation and/or failure of the appliance.
Installation
Combustion Air Requirements:
Natural Gas (G20)
10 m
3
/hr
LPG (G31)
9 m
3
/hr