Specifications
Gas Supply Requirements
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
*
- Measure burner operating pressure at gas control valve outlet test point with burner operating at
‘High’ setting. Operating pressure is ex-factory set, through the appliance regulator and not to
be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Gas Connection
Bench Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 55mm from floor and is reached from rear of appliance. (Refer to
‘Dimensions’ section).
Connection is
¾"
BSP male (For all other models).
All Other Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 655mm from floor and is reached from beneath appliance. (Refer to
‘Dimensions’ section).
Connection is
¾"
BSP male (For all other models).
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
Natural Gas (G20)
Propane (G31)
GP8600G
GP8900G
GP8120G
GP8600G
GP8900G
GP8120G
Heat Input (nett)
13.3 kW
21 kW
28.5 kW
13.3 kW
21 kW
28.5 kW
Gas Rate (nett)
1.41 m
3
/hr
2.22 m
3
/hr
3.02 m
3
/hr
1.03 kg/hr
1.63 kg/hr
2.21 kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating
Pressure
8.5 mbar (*)
8.2 mbar (*)
Gas Connection
3
/
4
” BSP Male
26 mbar (*)
Natural Gas
LP Gas (Propane)
GP8600G
GP8900G
GP8120G
GP8600G
GP8900G
GP8120G
Input Rating
(N.H.G.C.)
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
Supply
Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
Operating
Pressure
0.85 kPa (*)
(3.4” w.c.)
0.90 kPa (*)
(3.6”w.c.)
2.5 kPa (*)(9.8”
w.c.)
Gas
Connection
¾” BSP Male
2.6 kPa (*)
(10.2” w.c.)
Summary of Contents for GP120G