12
Installation
7.
Check gas operating pressure is as shown in ‘Specifications’ section.
NOTE: Operating pressure is to be measured
at burner operating pressure test point
outlet and with one griddle burner
operating at the ‘High Flame’ setting.
8.
Turn ‘Off’ mains gas supply and bleed gas
out of appliance gas lines.
9.
Turn ‘On’ gas supply and appliance.
10. Verify operating pressure remains correct.
Commissioning
Before leaving the new installation;
Check the following functions as shown in operating instructions specified in ‘Operation’ section of
this manual.
Light the Pilot Burner.
Light the Main Burner.
Turning 'Off' the Main Burner / Pilot.
Ensure operator has been instructed in areas of correct lighting, operation, and shutdown procedure
for appliance.
This manual must be kept by owner for future reference and a record of
Date of Purchase,
Date of
Installation
and
Serial Number of Appliance
must be recorded and kept with this manual.
(These
details can be found on Rating Plate, refer to ‘Dimensions’ section for locations of Rating Plate
for different applications. Also refer to ‘Gas Connection’ section)
.
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas
supply and contact supplier of this appliance.
For Refrigeration Cabinet Installation refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
Burner Operating Pressure
Test Point (Outlet)
Fig 3
Summary of Contents for GP120G
Page 27: ......