3
Model Numbers Covered in this Specification
CH8300G-
Gas Chargrill, 300mm wide.
CH[1]8450G-[2]
Gas Chargrill, 450mm wide.
CH[1]8600G-[2]
Gas Chargrill, 600mm wide.
CH[1]8900G-[2]
Gas Chargrill, 900mm wide.
CH[1]8120G-[2]
Gas Chargrill, 1200mm wide.
NOTE:
[1]: - Model Options;
-
- Standard Models.
L
- Low Back Models.
B
- Bold Front.
LB
- Low Back and Bold Front.
[2] - Base Stand Options;
B
- Bench Mount.
CB - Cabinet Base (excluding RN8200G Series).
LS - Leg Stand (excluding RN8200G Series).
RB - Refrigerated Base (RN8600G and RN8800G Series only).
Gas Supply Requirements
- Australia:
- New Zealand):
* - Measure burner operating pressure at the manifold test point with one burner for CH8300G and
CH8450G models or two burners for other models operating at full setting. Operating pressure is
ex-factory set and not to be adjusted, apart from when converting between gases, if required.
(Refer to ‘Gas Conversion’ section for details).
Specifications
Natural Gas
LP Gas (Propane)
CH8300G CH8450G CH8600G CH8900G CH1200G CH8300G CH8450G CH8600G CH8900G CH1200G
Input Rating (N.H.G.C.)
33.0 MJ/hr 48.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr 133 MJ/hr 33.0 MJ/hr 48.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr 133 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating
Pressure (*)
1.0 kPa
0.95 kPa
2.5 kPa
2.6 kPa
Gas Connection
1
/
2
” BSP
Male
3
/
4
” BSP Male
1
/
2
” BSP
Male
3
/
4
” BSP Male
Natural Gas
LP Gas
CH8300G CH8450G CH8600G CH8900G CH1200G CH8300G CH8450G CH8600G CH8900G CH1200G
Input Rating (N.H.G.C.)
33.0 MJ/hr 48.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr 133 MJ/hr 34.5 MJ/hr 50.4 MJ/hr 69.1 MJ/hr 103.6 MJ/hr 138.2MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating
Pressure (*)
1.0 kPa
0.95 kPa
2.5 kPa
2.6 kPa
Gas Connection
1
/
2
” BSP
Male
3
/
4
” BSP Male
1
/
2
” BSP
Male
3
/
4
” BSP Male
Summary of Contents for CH8300G