Waldorf CH8300G Installation And Operation Manual Download Page 13

11 

Installation

 

Gas Connection 

NOTE:  ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. 

 

1. 

Waldorf Chargrills do not require an electrical connection, as they function on gas supply only. 

2. 

It is essential that gas supply is correct for chargrill to be installed and that adequate supply pressure 

and volume is available.  The following checks should be made before installation: 

a.  Gas Type the appliance has been supplied for is shown on a coloured sticker located above gas 

entry point and on the rating plate.  Check these are correct for gas supply appliance is being 

installed for.  Gas conversion procedure is detailed in ‘Gas Conversion and Specification’ section of 
this manual. 

b.  Supply Pressure required for this appliance is shown in 'Specifications' section of this manual.  

Check gas supply to ensure that adequate supply pressure exists. 

c.  Input Rate of this appliance is shown on Rating Plate and in 'Specifications' section of this 

manual.  Input rate should be checked against available supply line capacity.  Particular note 
should be taken if chargrill is being added to an existing installation.
 

 

NOTE:  It is important that adequately sized piping runs directly to the connection point on the 

appliance with as few tees and elbows as possible to give maximum supply volume. 

 

3. 

Fit gas regulator supplied, into gas supply line as close to the appliance as possible. 

For CH8300, the regulator connection is ½" BSP female. Connection on unit is ½" BSP male. 

For all other models, regulator connection is ¾" BSP female.  Connection on unit is ¾" BSP 

male. 
(Refer to ‘Specifications’ section for gas supply location dimensions). 

 

NOTE: 

 

Gas pressure regulator provided with this appliance is convertible between Natural Gas 

and LPG as shown in the ‘Gas Conversion Section’ in this manual. 

 

Ensure the regulator is converted to the correct gas type that appliance will operate 
on.  Regulator outlet pressure is fixed ex-factory for gas type that regulator is 

converted to and it is NOT to be adjusted. 

 

4. 

A suitable joining compound which resists the breakdown action of LPG, must be used on every gas 

line connection, unless compression fittings are used. 

 

NOTE:  A manual isolation valve must be fitted to individual appliance supply line. 

 

5. 

Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that 

the appliance is level and at the correct height. 

6. 

Connect gas supply to the appliance. 

7. 

Check gas operating pressure is as shown in 'Specifications' section. 

8. 

Check all gas connections for leakage using soapy water or other gas detecting equipment. 

NOTE:  Measure the burner operating pressure at the 

manifold test point with one burner, for 

CH8300G and CH8450G models or two 

burners, for other models, operating at full 
setting.  Operating pressure is ex-factory set 

and not to be adjusted, apart from when 

converting between gases, if required.  (Refer 

to ‘Gas Conversion’ section for details).

 

Fig 2 

Manifold 

Test Point 

 
 

D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

Warning 

Summary of Contents for CH8300G

Page 1: ...ill CH8300G CHL8300G CH8450G CHL8450G CH8600G CHL8600G CH8900G CHL8900G CH8120G CHL8120G Date Purchased Serial Number Dealer Service Provider 228592 38 For use in GB IE DK CHB8300G CHLB8300G CHB8450G...

Page 2: ...ares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 14...

Page 3: ...ons 5 Installation 8 Installation Requirements Unpacking Location Clearances Assembly Fitting Adjustable Feet Rear Rollers to Leg Stand Units Gas Connection Commissioning Operation 13 Operation Guide...

Page 4: ...N UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHE...

Page 5: ...and not to be adjusted apart from when converting between gases if required Refer to Gas Conversion section for details Specifications Natural Gas LP Gas Propane CH8300G CH8450G CH8600G CH8900G CH1200...

Page 6: ...kW 36 0 kW Reduced 3 5 kW 4 2 kW 6 0 kW 9 0 kW 18 0 kW 3 7 kW 4 3 kW 6 4 kW 9 6 kW 12 8 kW Gas Rate nett Nominal 0 93 m3 hr 1 38 m3 hr 1 90 m3 hr 2 86 m3 hr 3 81 m3 hr 0 68 kg hr 1 01 kg hr 1 40 kg hr...

Page 7: ...5 Dimensions CH L 8120G B CH L 8600G B CH L 8900G B CH L 8450G B CH L 8300G B NOTE The CH8300G are available in Bench Model B Option Only...

Page 8: ...6 Dimensions CH L 8600G LS CH L 8450G LS...

Page 9: ...7 Dimensions CH L 8900G LS CH L 8120G LS R...

Page 10: ...section will void the warranty Components having adjustments protected e g paint sealed by manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the insta...

Page 11: ...ls will require assembly Refer to Fitting of Adjustable Feet Rollers to Leg Stand Units information on the following page for assembly instructions Rear leg housings can be fitted with a Adjustable fe...

Page 12: ...itted with rear rollers to enable appliance to be easily moved for positioning and cleaning purposes If desired these rollers are supplied in the packaging with the appliance Rear Adjustable Feet fitt...

Page 13: ...ulator connection is BSP female Connection on unit is BSP male For all other models regulator connection is BSP female Connection on unit is BSP male Refer to Specifications section for gas supply loc...

Page 14: ...has been instructed in the areas of correct lighting operation and shutdown procedure for this appliance 2 This manual must be kept by the owner for future reference and a record of Date of Purchase...

Page 15: ...h burner flame viewing ports This appliance is for professional use and is only to be used by qualified persons Only authorised service persons are to carry out installation servicing or gas conversio...

Page 16: ...me can be selected by depressing gas control knob and rotating fully anti clockwise 3 For intermediate heat position gas control knob between HIGH and LOW positions for the desired heat setting 4 Duri...

Page 17: ...iddle plate 3 Fit Griddle Plate Item A or Item B as required Fig 4 Chargrill Grate Reversal The grates can be fitted to the chargrill in either of two ways They can be fitted in the FLAT position Fig...

Page 18: ...ould be checked and emptied frequently to prevent overflow and spillage Remove crumb tray s while still warm so that grease is in a liquid state Empty any grease from trays and wash thoroughly in same...

Page 19: ...and a scrubbing brush Dry all radiants thoroughly with a dry cloth Griddle Plate Optional Extra a Remove and clean grease collection drawer frequently to prevent over spills b Clean griddle surface th...

Page 20: ...regular and thorough and all controls and mechanical parts checked and adjusted periodically by a competent serviceman If any small faults occur have them attended to promptly Don t wait until they c...

Page 21: ...paint sealed by the manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by an unqualified service person This section provides an easy reference guide to t...

Page 22: ...ing Main burners Inner radiants chargrill castings griddle plates Pilot Burners 1 Disconnect the following Gas supply tube to pilot burner 2 Remove pilot injectors and replace with correct size pilot...

Page 23: ...ype labels located at The rear of the unit above the gas connection Beside the rating plate Commissioning Before leaving the converted installation 1 Check all gas connections for leakages using soapy...

Page 24: ...mm 1 65mm Pilot Burner Injectors 0 35 0 45 0 25 0 30 Low Fire Adjustment 11 4 turns out ccw 17 8 turns out ccw 11 4 turns out ccw turn out ccw 11 4 turns out ccw turn out ccw 1 0 kPa 0 95 kPa 2 5 kPa...

Page 25: ...hen converting between gases if required Refer to Gas Conversion section for details Natural Gas G20 Propane G31 CH8300G CH8450G CH8600G CH8900G CH8120G CH8300G CH8450G CH8600G CH8900G CH8120G Main Bu...

Page 26: ...Burner Injectors 2 70mm 3 50mm 2 70mm 4 50mm T B A 4 50mm Pilot Burner Injectors 0 35 0 45 0 60m 0 75mm Low Fire Adjustment 11 4 turns out ccw 17 8 turns out ccw 11 4 turns out ccw 2 turns out ccw Bu...

Page 27: ...227508 PIEZO SIT 228010 PIEZO HOUSING 019428 THERMOCOUPLE 320mm M9 x 1 019218 THERMOCOUPLE 450mm 227404 GAS VALVE 21S 231540 SPARK ELECTRODE 019624 ELECTRODE 229731 HT LEAD 250mm RING TERMINAL 228047...

Page 28: ...230185 BSP F F Adjustable BSP F F Convertible Gas Regulators Gas Conversion Kits Optional Accessories Description Part No Casting Scraper Tool 228787 Smooth Plate Scraper Blades Pack of 5 blades 22856...

Page 29: ......

Reviews: