3
Model Numbers Covered in this Specification
CH8300G-
Gas Chargrill, 300 mm wide.
CH
[1]
8600G-
[2]
Gas Chargrill, 600 mm wide.
CH
[1]
8900G-
[2]
Gas Chargrill, 900 mm wide.
CH
[1]
8120G-
[2]
Gas Chargrill, 1200 mm wide.
NOTE:
[1]: -
- Standard Back Models.
L
- Low Back Models.
[2]: LS
- On Leg Stand.
B
- Bench Models
Gas Supply Requirements
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P
(20, 30 / 37),
II
2H3B/P
(20, 30).
Flue Type:
A
1.
* - Measure burner operating pressure at the manifold test point with one burner for CH8300G model or
two burners for other models operating at full setting. Operating pressure is ex-factory set and not
to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Specifications
Natural Gas
LP Gas (Propane)
CH8300G
CH8600G
CH8900G
CH8120G
CH8300G
CH8600G
CH8900G
CH8120G
Input Rating
(N.H.G.C.)
33.0 MJ/hr
66.0 MJ/hr
100.0 MJ/hr
133 MJ/hr
33.0 MJ/hr
66.0 MJ/hr
100.0 MJ/hr
133 MJ/hr
31,270 Btu/hr 62,500 Btu/hr 94,700 Btu/hr 126,000 Btu/hr 31,270 Btu/hr 62,500 Btu/hr 94,700 Btu/hr 126,000 Btu/hr
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18.0” w.c.)
Burner Operating
Pressure
1.0 kPa (*)
0.95 kPa (*)
2.5 kPa (*)
2.6 kPa (*)
(4” w.g.)
(3.8” w.g.)
(9.8” w.g.)
Gas Connection
1
/
2
” BSP Male
3
/
4
” BSP Male
1
/
2
” BSP Male
3
/
4
” BSP Male
(10.0” w.g.)
Natural Gas (G20)
Propane (G31)
CH8300G
CH8600G
CH8900G
CH8120G
CH8300G
CH8600G
CH8900G
CH8120G
Heat Input
(nett)
Nominal
8.8 kW
18.0 kW
27.0 kW
36.0 kW
8.8 kW
18.0 kW
27.0 kW
36.0 kW
Reduced
3.5 kW
6.0 kW
9.0 kW
18.0 kW
3.7 kW
6.4 kW
9.6 kW
12.8 kW
Gas Rate
(nett)
Nominal
0.93 m
3
/hr
1.90 m
3
/hr
2.86 m
3
/hr
3.81 m
3
/hr
0.68 kg/hr
1.40 kg/hr
2.10 kg/hr
2.80 kg/hr
Reduced
0.37 m
3
/hr
0.63 m
3
/hr
0.95 m
3
/hr
1.27 m
3
/hr
0.29 kg/hr
0.50 kg/hr
0.75 kg/hr
0.99 kg/hr
Supply Pressure
20 mbar
30 / 37 mbar
Burner Operating
Pressure
10.6 mbar (*)
25 mbar (*)
26 mbar (*)
Gas Connection
1
/
2
” BSP Male
3
/
4
” BSP Male
1
/
2
” BSP Male
3
/
4
” BSP Male
10 mbar (*)
Butane (G30)
CH8300G
CH8600G
CH8900G
CH8120G
Heat Input
(nett)
Nominal
9.6 kW
19.2 kW
28.8 kW
38.4 kW
Reduced
2.0 kW
4.0 kW
6.0 kW
8.0 kW
Gas Rate
(nett)
Nominal
0.76 kg/hr
1.44 kg/hr
2.27 kg/hr
3.03 kg/hr
Reduced
0.16 kg/hr
0.32 kg/hr
0.47 kg/hr
0.63 kg/hr
Supply Pressure
30 mbar
Burner Operating
Pressure
25 mbar (*)
26 mbar (*)
Gas Connection
1
/
2
” BSP Male
3
/
4
” BSP Male
Summary of Contents for CH8300G
Page 24: ......