5
NOTE:
It is most important that this appliance is installed correctly and that operation is
correct before use. Installation shall comply with local gas, electrical and health and
safety requirements.
This appliance shall be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of health harmful substances in the room, appliance is
installed in.
Waldorf 'FAST-FRI' HPO Fryers are designed to provide years of satisfactory service, and correct installation
is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas, electrical, fire and health and safety.
Australia / New Zealand:
- AS5601.1 - Gas Installations.
Australia / New Zealand:
- AS / NZS3000 - Wiring Rules.
Installation must be carried out by authorised persons only. Failure to install equipment to
relevant codes and manufacturers specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Remove all packaging and transit protection from appliance, including all protective plastic coating
from door, outer panels and exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate located behind access door.
Check the following parts have been supplied with the appliance:-
FN8130GHPO
Baskets
2
Basket Grids
1
Lid
1
Drain Stick
1
Drain Extension
1
1.
This appliance must be installed in a suitably ventilated room to prevent dangerous build up of
combustion products.
2.
Installation must allow for a sufficient flow of fresh air for combustion air supply. Combustion air
requirements:-
Combustion Air Requirements
All Gas Types
24 m³/hr minimum.
3.
Never directly connect a ventilation system to the appliance flue outlet.
4.
A minimum of 610mm clearance must be maintained from flue outlet to any above surface.
5.
Position appliance in its approximate working position.
6.
All air for burner combustion is supplied from beneath the unit. Legs must always be fitted and no
obstructions placed beneath or around base of fryer, as obstructions will cause incorrect operation
and / or failure of the fryer.
NOTE: Do not obstruct or block the appliance flue. Never directly connect a ventilation
system to the appliance flue outlet.