background image

NOTE: 

 

It  is  most  important  that  this  appliance  is  installed  correctly  and  that  operation  is  

correct before use.  Installation shall comply with local gas, electrical and health and 

safety requirements. 

 

This appliance shall be installed with sufficient ventilation to prevent the occurrence 

of unacceptable concentrations of health harmful substances in the room, appliance is 

installed in. 

 

Waldorf 'FAST-FRI' HPO Fryers are designed to provide years of satisfactory service, and correct installation 

is essential to achieve the best performance, efficiency and trouble-free operation. 

This appliance must be installed in accordance with National installation codes and in addition, in  

accordance with relevant National / Local codes covering gas, electrical, fire and health and safety. 

 

Australia / New Zealand: 

 - AS5601.1 - Gas Installations. 

Australia / New Zealand: 

 - AS / NZS3000 - Wiring Rules. 

 

Installation must be carried out by authorised persons only.  Failure to install equipment to 

relevant codes and manufacturers specifications shown in this section will void the warranty. 
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be 

adjusted  by  an  authorised  service  agent.  They  are  not  to  be  adjusted  by  the  installation  

person. 

 

 

 

Remove all packaging and transit protection from appliance, including all protective plastic coating 

from door, outer panels and exterior stainless steel panels. 

 

Check equipment and parts for damage.  Report any damage immediately to carrier and distributor. 

 

Report any deficiencies to distributor who supplied appliance. 

 

Check available gas supply is correct to as shown on rating plate located behind access door. 

 

Check the following parts have been supplied with the appliance:- 

 

 

FN8130GHPO 

Baskets 

Basket Grids 

Lid 

Drain Stick 

 

Drain Extension 

 

 

1. 

This appliance must be  installed in a suitably ventilated room to prevent dangerous build up of  

combustion products. 

2. 

Installation must allow for a sufficient flow of fresh air for combustion air supply.  Combustion air 

requirements:- 

 

Combustion Air Requirements 
All Gas Types 

24 m³/hr minimum. 

 

3. 

Never directly connect a ventilation system to the appliance flue outlet. 

4. 

A minimum of 610mm clearance must be maintained from flue outlet to any above surface. 

5. 

Position appliance in its approximate working position. 

6. 

All air for burner combustion is supplied from beneath the unit.  Legs must always be fitted and no 

obstructions placed beneath or around base of fryer, as obstructions will cause incorrect operation 

and / or failure of the fryer. 

 

NOTE:  Do  not  obstruct  or  block  the  appliance  flue.    Never  directly  connect  a  ventilation  

system to the appliance flue outlet. 

Summary of Contents for 800 SERIES

Page 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l FN8130GHPO FNL8130GHPO HPO Fast Fri Gas Fryer 228686 21 FNB8130GHPO FNLB8130GHPO...

Page 2: ...vice tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Li...

Page 3: ...Clearances Assembly Electrical Connection Fitting Rear Rollers Gas Connection Commissioning Operation Guide Description of Controls Filling the Tank Lighting Main Burners Setting Operating Temperature...

Page 4: ...LY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION...

Page 5: ...8130GHPO 220 240 V a c 50 Hz 0 5A 1P N E 3 pin 10A cord set fitted Input Rating N H G C 140 MJ hr 140 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 3 40 kPa Burner Operating Pressure 0 87 kPa 2 55 kPa Gas...

Page 6: ...4...

Page 7: ...lation person Remove all packaging and transit protection from appliance including all protective plastic coating from door outer panels and exterior stainless steel panels Check equipment and parts f...

Page 8: ...he appliance can be positioned securely and level This should be carried out on completion of gas connection Refer to Gas Connection Section This appliance can also be fitted with rear rollers to enab...

Page 9: ...housings 3 Fit rear roller to rear leg housing and align screw hole in side of rear leg housing with threaded hole in rear roller 4 Secure rear roller to leg support with bolt supplied and tighten bo...

Page 10: ...installed for Gas conversion procedure is shown in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure adequate supp...

Page 11: ...al b Thermostat operation check should be carried out by filling the fryer with oil shortening to the oil FILL LEVEL mark at rear of the tank and setting the thermostat to 180 C Turn ON main burners a...

Page 12: ...ed Press and release to operate Located Behind Main Access Door GREAT CARE MUST BE TAKEN BY OPERATOR TO USE THE FRYER SAFELY TO GUARD AGAINST RISK OF INJURY AND FIRE DO NOT LEAVE FRYER UN ATTENDED DUR...

Page 13: ...oiling table burner The liquefied shortening can then be poured into the tank until it reaches the FILL LEVEL mark FN8130GHPO fryer will hold 46 5 lbs shortening Pre Heating NOTE When pre melting shor...

Page 14: ...control panel will illuminate when burners are On and will go out when oil is at pre set temperature 5 If left or right Red Lock Out indicators illuminate press left or right burner reset switches on...

Page 15: ...and operating at peak efficiency follow the procedures below 1 At end of each day or at the end of each shift if frying schedule is heavy frying medium should be drained and filtered into a receptacle...

Page 16: ...ained use a ladle or small pan with a handle and dip into hot frying medium from container and pour around sides and bottom of tank to wash out crumbs and particles adhering to tank 9 Continue to dip...

Page 17: ...er and rinse thoroughly with water Use a 1 part vinegar to 15 parts water solution to rinse tank and neutralise any cleaner residue If this proves unsuitable for cleaner being used use a weaker soluti...

Page 18: ...rying oil broken down Check amount of fresh frying medium added to fryer to be sure turnover is adequate Using wrong cooking frying medium Some frying mediums form gums when used in a deep fryer e g s...

Page 19: ...hermostat setting with a thermometer or thermocouple Rapid breakdown of oil Use a stable frying oil Use of unrefined oils Dripping smokes at lower temperature than refined and deodorised oils Darkenin...

Page 20: ...ply not On Incorrect gas pressure Incorrect injectors Faulty gas valve Does the flame continue well after sparking stops Broken connection from flame rod to control Bad earthing no poor circuit burner...

Page 21: ...19...

Page 22: ...ng bracket 5 Reconnect supply pipe at universal joint 6 Fasten supply pipe to upper mounting bracket 7 Retighten universal joint 8 Attach the supplied 3 4 Male Female galvanised elbow at the end of th...

Page 23: ...correct plates Refer to Gas Specifications Table at end of this section 1 Connect a manometer to lower test point Operating Pressure on the gas control valve Refer to Fig 12 2 Remove slotted cap to r...

Page 24: ...as connections for leakage using soapy water or other gas detecting equipment 2 Check the following functions in accordance with operating instructions specified in Operation section of this manual Li...

Page 25: ...x 9 55 holes 16 x 9 55 holes Operating Pressure 0 87 kPa 2 55 kPa Supply Pressure 1 13 3 40 kPa 2 75 3 40 kPa Main Burner Injectors 4 30mm 2 40mm Aeration Plate 20 x 9 55 holes 16 x 9 55 holes Operat...

Page 26: ...tch 023160K Burner Blower Kit 024792 Ignition Electrode spark 025383 Ignition Electrode flame 022663 Fuse 2 Amp 227963 Heating indicator Amber 227962 Power Indicator Green 013528 Lock Out Indicator Re...

Page 27: ......

Reviews: