22
On completion of the gas conversion, replace the gas type identification label located at:-
- Rear of appliance, above the gas connection point.
- Beside rating plate.
Before leaving the converted installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with operating instructions specified in 'Operation'
section of this manual.
Light the Main Burners.
Check the Thermostat operation.
Ensure all controls operate correctly.
NOTE: If it is not possible to get the appliance to operate correctly, shut ‘Off’ gas supply and
contact the supplier of this unit.