background image

 

500.0024-A

 

Subject to technical changes

 

3.2.

 

Locking the safe

 

 

1.

 

Close the door while the 

rotary opening 

handle is in the "open" position

 
 

 

2.

 

Turn the rotary opening handle 
counterclockwise into the "closed" 
position (lock closes automatically). 

Wait for the "Lock closed!" 
message on the display.

 

 
 

 

3.

 

Gently press the rotary opening handle 
clockwise to check whether the lock 

 

and therefore the safe 

 are locked. 

 

 

3.3.

 

Opening the safe under threat

 

If the locking system is connected to an alarm installation, a silent alarm (which cannot be 
heard at your location) can be sent to the alarm centre when the code to open the safe is 
entered in the normal way. To trigger the threat alarm, the value of the 

last two digits

 of 

the opening code must be increased by three. This input sends an alarm and the lock 
opens (so as not to arouse suspicion). 

Make sure that the threat code does not result in a valid opening code! 

Explanation: 

Last digits of the opening code: 

Addition: 

Input: 

XXXXXX-96 

96 + 3 = 99 

XXXXXX99 

XXXXXX-97 

97 + 3 = 1

00

 

XXXXXX00 

XXXXXX98 

98 + 3 = 1

01

 

XXXXXX01 

XXXXXX99 

99 + 3 = 1

02

 

XXXXXX02 

XXXXXX00 

00 + 3 = 03 

XXXXXX03 

XXXXXX05 

05 + 3 = 08 

XXXXXX08 

 
Examples: 

Opening code: 

Threat code: 

192753

39

 

192753

42

 

192753

42

 

192753

45

 

192753

98

 

192753

01

 

Summary of Contents for PAXOS ADVANCE DUAL LOCK

Page 1: ...www tresore ch OPERATING INSTRUCTIONS SAFE LOCK PAXOS ADVANCE DUAL LOCK Electronic safe lock for WA safes...

Page 2: ...the EN1143 1 standard A Swiss quality product with security tested by the VdS German Association of Indemnity Insurers Before starting to use your strongbox please read these instructions thoroughly...

Page 3: ...ramming codes 7 3 4 1 User code 01 OCa1 and user code 02 OCb1 for lock 1 7 3 4 2 User code 01 OCa2 and user code 02 OCb2 for lock 2 8 3 4 3 Master code 00 MA1 8 3 4 4 Master code 00 MA2 9 3 5 Setting...

Page 4: ...s it easy and clear to operate Various additional functions can also be used with the Paxos Advance 1 1 Operating controls WALDIS First and Premium Input unit Rotary opening handle NOTE These operatin...

Page 5: ...l Pos 3 Arrow key up left Select the next menu item Select the next input value Pos 4 Arrow key down right Select the next menu item Select the next input value Pos 5 ENTER key Confirm inputs Call up...

Page 6: ...to release the battery case that is slotted into the input unit from below and swivel it downwards and outwards 3 The battery holder B is inserted in the battery case release it from the case and fit...

Page 7: ...ate time saved message 8 Press the ENTER key repeatedly and the display will show the Open menu message confirm this again with the ENTER key 9 The display shows the Lock code 1 message to indicate th...

Page 8: ...the display shows the Lock 1 is opening message followed by Lock is open The display then shows the Lock code 2 message to indicate that user code 1 or 2 for lock 2 12223310 or 12223320 must be enter...

Page 9: ...alarm which cannot be heard at your location can be sent to the alarm centre when the code to open the safe is entered in the normal way To trigger the threat alarm the value of the last two digits of...

Page 10: ...99 88 77 Battery code BC94 11 11 11 11 The lock cannot be opened with this code it is needed to define the employee codes and the time functions The Paxos Advance electronic high security lock is norm...

Page 11: ...pressing the ENTER key again 4 On the display use the arrow key to select Lock 2 and also confirm this with the ENTER key 5 Use any arrow key to select 01 OCa2 02 OCb2 and confirm with the ENTER key t...

Page 12: ...current codes 2 Leave the rotary opening handle in the open position 3 On the input unit press the ENTER key confirm the Code functions menu that is shown on the display by pressing the ENTER key aga...

Page 13: ...ine batteries LR6 E91 or AM3 into it As an option you can also insert a rechargeable battery pack A from Dorma Kaba in this case there is no need for the battery holder Operation with rechargeable bat...

Page 14: ...ossible section 3 6 The lock can be operated until the battery voltage drops below 6 5 volts No codes or settings are deleted when a battery is replaced You only need to check the date and time and re...

Page 15: ...ff 5 1 Assignment of terminals on the I O box The I O box has 8 inputs and 8 outputs connections for the power supply and an RS232 interface NOTE The I O box functions are only available when the I O...

Page 16: ...on Connection with tamper monitoring switch factory configuration 3 IN2 4 GND Input 2 Standard bypass opening delay 5 IN3 6 GND Input 3 Standard interrupt lockout time 16 IN4 17 GND Input 4 Standard e...

Page 17: ...at 50 C ext OUTx OUTx 9 OUT2 10 OUT2 Output 2 Standard all locks and door bolts open 11 OUT3 12 OUT3 Output 3 Standard resistance monitoring input sabotaged 22 OUT4 23 OUT4 Output 4 Standard external...

Page 18: ...itoring of external power supply Output voltage 24 VAC power load at output 0 4 A at 25 C 0 3 A at 50 C ext NC 39 COM 40 NO 41 14 VDC 15 GND External power supply 12 VDC 24 VDC 700 200 mA ext I O box...

Page 19: ...as far as possible the keypad shows signs of wear over time revealing the individual numbers used in the code Example of a good password Memorable sentence First letters of each word First letters in...

Reviews: