input unit confirms that the door (lock) is 
open until the door is closed again. 

 
 

7.

 

Programme the new code as per section 
3.3. 

 

 

 

Operation

 

 

Opening the safe

 

 

1.

 

First, press the rotary opening handle 
counterclockwise into the "closed" 
position to make sure that the lock bolt is 
relieved of pressure. 

 
 

 

2.

 

Press any key to activate the input unit. 
Enter the code and confirm it with the 
Enter key. Within 5 seconds 

after

 the 

short acoustic signal (six beeps), you 
must turn the rotary opening handle 
clockwise to the "open" position. 

 

 

3.

 

Open the door. A short acoustic signal 
(six beeps) every 30 seconds via the 
input unit confirms that the door is open 
until it is closed again. 

 

 

  

 

 

 

NOTE:

 Every keystroke is acknowledged by an acoustic signal. If you enter an incorrect 

code, you can delete the entire code with the DEL key and re-enter your code.

 

 

Summary of Contents for AXESSOR

Page 1: ...www tresore ch OPERATING INSTRUCTIONS SAFE LOCK AXESSOR Electronic safe lock for WA safes...

Page 2: ...the EN1143 1 standard A Swiss quality product with security tested by the VdS German Association of Indemnity Insurers Before starting to use your strongbox please read these instructions thoroughly...

Page 3: ...nals mean 2 Description of the keys 2 Description of display messages 2 Starting to use your safe 3 Operation 4 Opening the safe 4 Locking the safe 5 Reprogramming codes 5 Setting the time and date 6...

Page 4: ...e than the standard lock Operating controls WALDIS Eco and Business Input unit Rotary opening handle NOTE These operating instructions describe how to handle a safe in each case they show a version wi...

Page 5: ...pecialist dealer Description of the keys Pos 1 DEL key Delete Pos 2 MODE key Access to programming mode Pos 3 ENTER key Confirm input Pos 4 INF ESC key Lock information go back one menu level Pos 5 Ar...

Page 6: ...llen key 3 Carefully pull the battery case downwards out of the input unit housing six acoustic signals and insert three 1 5 V AA alkaline batteries LR6 or 1 5 V AA lithium batteries FR6 into the batt...

Page 7: ...e 2 Press any key to activate the input unit Enter the code and confirm it with the Enter key Within 5 seconds after the short acoustic signal six beeps you must turn the rotary opening handle clockwi...

Page 8: ...opening of the safe must be performed and it must be repaired or replaced at the owner s expense The certification lapses in case of a repair Procedure 1 Open the door with the current code 2 Leave t...

Page 9: ...open and the rotary opening handle in the open position press the Mode key the display shows PRG MOD 2 Input the existing master code confirm with the Enter key and the display will show TIME 3 Confir...

Page 10: ...key The display shows BATCASE OPEN To delete this message again enter the opening code and confirm it with the Enter key Malfunctions Battery If there is insufficient battery voltage the display show...

Page 11: ...y or any car registration numbers or phone numbers Don t use a code that you already use elsewhere How should a code be structured The code should not have a logical structure Use all the keys as far...

Reviews: