1.4 Specifications
Electrical
50/60 Hz, single phase
EHB/EZB
115
VAC
±
10%
0.9 Amp max.
16 watt avg.
230
VAC
±
10%
0.4 Amp max.
16 watt avg.
EHC/EZC
115
VAC
±
10%
1.4 Amp max.
24 watt avg.
230 VAC
±
10%
0.6 Amp max.
24 watt avg.
Operating Conditions
Ambient
temperature
32
°
F to 122
°
F (0
°
C to 50
°
C)
Relative humidity
30% to 90% non-condensing
Liquid temperature
32° to 104°F (0 to 40°C) for PVC based liquid ends
32° to 140°F (0 to 60°C) for PP, PVDF, SS based liquid ends
Capacity/Pressure Rating
Maximum
Output Capacity
Output
per Stroke (mL)
Maximum
Pressure
3
Size
(Gal/hr) (mL/min) Min.
Max.
PSI
MPa
Connection
Size (in)
Tubing O.D
2
B10
1
0.6 38 0.05
0.11 150 1.0
3/8
B10(H)
0.5 30 0.04
0.08 215 1.5
3/8
B15
1
1.0 65 0.09
0.18 105 0.7
3/8
B20
1
1.5 95 0.13 0.26 60 0.4
3/8
B30
1
3.2 200 0.28 0.56 30 0.2
1/2
C15
1.3 80 0.09
0.22 150 1.0
3/8
C15(H)
0.8 50 0.06
0.14 215 1.5
3/8
C20
2.0 130 0.14 0.36 105 0.7
3/8
C30
4.3 270 0.30 0.75 50 0.35
1/2
C35
4
6.7
4
420
4
0.46 1.17 30 0.2
1/2
1
Available sizes for EZ pumps
2
1/4” NPT female for 316 SS
3
Auto Air vent valve reduces maximum pressure approx. 35 PSI (0.2 MPa)
4
EZC35 rated output is 6.3 GPH (400 ml/min)
Adjustment Range
Stroke length adjustment range
40% to 100% (EHB and EHC only)
Frequency adjustment range
0 to 360 strokes per minute
Materials of Construction
Liquid End
Code
Pump Head
& Fittings
Diaphragm
Valve
Balls
Valve
Seat
Valve
Seals
Gasket Tubing
PC
GFRPP CE
FKM
FKM
PE
GFRPP CE
EPDM
EPDM
VC
PVC CE
FKM
FKM
VE
PVC CE
EPDM
EPDM
VF
PVC PTFE
EPDM
EPDM
TC
PVDF CE
FKM
FKM
FC
PVDF CE
PCTFE
PTFE
PE
SH
SS
PTFE
(bonded to
EPDM)
HC HC PTFE
PTFE
¼” NPTF
CE
Alumina
ceramic
PE
Polyethylene
EPDM Ethylene propylene diene monomer
PTFE Polytetrafluoroethylene
FKM
Fluoroelastomer
PVC
Polyvinylchloride
(translucent)
GFRPP Glass fiber reinforced polypropylene
PVDF Polyvinylidenefluoride
HC
Hastelloy
C276
SS
316
stainless
steel
PCTFE
Polychlorotrifluoroethylene
Summary of Contents for EH Series