Carina IP Panic Button User’s Guide
Page 8
v
3.0.0.20201022
Getting Started
1.
All Carina devices should be configured within the Carina Event
Manager’s configuration webpages. While it is possible to make
changes at the device’s own webpages, any configuration changes to
the device’s webpages will be
overwritten
by the Event Manager.
2.
Locate and note your IP Panic Button’s MAC address. It is printed on a
white sticker located on the rear of the device.
3.
Connect the IP Panic Button’s main Ethernet port—labeled
LAN
—to a
network using a Power-over-Ethernet (PoE) Ethernet connection. When
connected, it will power on immediately, and the
LINK/ACTV
status LED
will begin to blink.
4.
Your Carina Event Manager will automatically detect the
Carina IP Panic
Button when you power up and connect to the network via PoE.
5.
On the Event Manager’s Web interface, navigate to the Devices page to
discover your IP Panic Button’s IP address. Look for the device matching
the MAC address you noted in step two.
6.
Following the instructions in the next sections, change Event Manager
settings for your Carina IP Panic Button as needed.
7.
To apply changes and settings to your Carina IP Panic Button,
save
changes
and
reprovision
your intercom. This is an important step!
Your
changes in Event Manager will not take effect at the IP Panic Button
until you have reprovisioned the endpoint.