background image

18

3. Connect  a  standard  network  cable  from  Switch/workstation  to 

“Ethernet”

 port of IPOE-162.

4. Connect  the  UTP  cable  from 

“Ethernet”

  port  of  IPOE-162S  to  the 

RJ-45 port of remote device.

5. Adjust  proper  DC  voltage  power  output  and  connect  DC  plug  from 

“Power Output”

 of IPOE-162S to remote device.

6. Power on the remote device and its power LED indicator will remains 

on.

Power Line

1000Base-T UTP

PoE

1000Base-T UTP with PoE

IPOE-162

Industrial

Switch

Power

Supply

AC 24V/DC 24~48V

IPOE-162 + IPOE-162S Installation

-40

 ℃

75

 ℃

802.3at

PoE Splitter

Power

Data

Power

DC

PTZ Camera

12V/24V DC Output

PoE

Power

Data

Data

100 meters

Note

1.  According  to  IEEE  802.3at  Power  over  Ethernet,  the 

IPOE-162  will  not  inject  power  to  the  cable  if  not 
connecting to IEEE 802.3at devices.

2.  Please  ensure  the  output  voltage  is  correct  before 

applying  power  to  remote  device.  Otherwise,  it  will 
damage the Powered Device (PD).

Summary of Contents for IPOE-162

Page 1: ...orgung zu den Touch Panels TP 7 und TP 10 mittels Power over Ethernet Das Ger t wird in der Verteilung eingebaut Es ben tigt eine Spannungsversorgung 24VDC Es wird in die LAN Verbindung von der Zentra...

Page 2: ...Industrial IEEE 802 3at af Gigabit PoE Injector IPOE 162 User s Manual...

Page 3: ...ysical Dimension 8 4 2 Product Outlook 9 4 3 Industrial PoE Injector Upper Panel 10 4 4 Wiring the Power Inputs 10 4 5 Wiring the Fault Alarm Contact 12 5 Mounting Installation 13 5 1 DIN Rail Mountin...

Page 4: ...njector and carefully unpack it The box should contain the following items IPOE 162 Industrial IEEE 802 3at Gigabit High Power over Ethernet Injector x 1 l l User s Manual x 1 l l DIN Rail Kit x 1 l l...

Page 5: ...Span PSE IEEE 802 3at 802 3af PoE compliant IEEE 802 3at 802 3af splitter devices compatible Support PoE Power up to 30 Watts for PoE port Provides DC 56V power over RJ 45 Ethernet cable to device wi...

Page 6: ...ration temperature Note PD Powered Device is a PoE enabled terminal by PSE and thus consumes energy such as IP Phones network cameras and Wireless access points etc PSE Power Sourcing Equipment is a d...

Page 7: ...3 4 5 up to 100m 328ft 100Base TX UTP Cat 3 4 5 up to 100m 328ft 1000Base T UTP Cat 5 5e 6 up to 100m 328ft EIA TIA 568 100 ohm STP 100m Data Rate 10 100 1000Mbps Dimension W x D x H 135 x 97 x 32 mm...

Page 8: ...02 3ab 1000Base T Gigabit Ethernet IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet enhancement standard FCC FCC Part 15B Class A CE EMI EN 55022 EN 61000 3 2 EN 61000 3 3 EMS EN 6100...

Page 9: ...ion Side View Bottom View Front View Top View Mounting Kit Mounting Kit DIN Rail Kit Rear View 10 100 1000T 10 100 1000T Ethernet DC Ethernet PoE In Use IPOE 162 P1 P2 FAULT 802 3at Input DC 24 48V AC...

Page 10: ...E 162 P1 P2 FAULT 802 3at Figure 4 2 LED Indicators LED Color Function P1 Green Indicate the power 1 has power P2 Green Indicate the power 2 has power FAULT Green Indicate the either power 1 or power...

Page 11: ...power inputs Figure 1 shows the upper panel of the Industrial PoE Injector 1 2 3 4 5 6 Figure 1 Industrial PoE Injector Upper Panel 4 4 Wiring the Power Inputs The 6 contact terminal block connector...

Page 12: ...for POWER 1 or 5 and 6 for POWER 2 1 2 3 4 5 6 Figure 2 Power input PINs 2 Tighten the wire clamp screws for preventing the wires from loosing 1 2 3 4 5 6 Power 1 Fault Power 2 Figure 3 PWR1 PWR2 Pin...

Page 13: ...t status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Insert the wires into the fault alarm contacts...

Page 14: ...PLANET 8 Port Industrial Gigabit Switch as the example However the steps for PLANET Industrial slim type Switch Industrial Media Serial Converter and Industrial PoE equipment are similar 5 1 DIN Rail...

Page 15: ...track Figure 7 Industrial Equipment installed in DIN Rail mount 5 2 Remove DIN Rail Mounting Step 1 Please refer to following procedures to remove the Industrial Equipment from the track 1 2 Figure 8...

Page 16: ...dustrial Equipment loose the screws to remove the DIN Rail Step 2 Place the wall mount plate on the rear panel of the Industrial Equipment Figure 9 Attach Brackets to the Industrial Equipment Step 3 U...

Page 17: ...ed device the IPOE 162 with POE 162S IPOE 162S can provide you a way to supply DC power for this Ethernet device conveniently and easily Note The IPOE 162 with IPOE 162S POE 162S is installed in pair...

Page 18: ...acceptable DC power range is from 52 to 56V DC Otherwise it will damage the Powered Device PD 2 If the connected device PD is not fully complying with IEEE 802 3at Power over Ethernet or in line powe...

Page 19: ...or will remains on Power Line 1000Base T UTP PoE 1000Base T UTP with PoE IPOE 162 Industrial Switch Power Supply AC 24V DC 24 48V IPOE 162 IPOE 162S Installation 40 75 802 3at PoE Splitter Power Data...

Page 20: ...t information please contact PLANET switch support team PLANET online FAQ http www planet com tw en support faq php type 2 Switch support team mail address support_switch planet com tw Copyright PLANE...

Page 21: ...22 Class A 2010 EN 55024 2010 IEC 61000 4 2 2008 IEC 61000 4 3 2006 A1 2007 A2 2010 IEC 61000 4 4 2004 A1 2010 IEC 61000 4 5 2005 IEC 61000 4 6 2008 IEC 61000 4 8 2009 Responsible for marking this dec...