23
246.805.201
Date: 2017-09-26
Adjustable parameters
Menu
Description
Range
Default
MAN SPEED
Speed for manual driving
200 – 2500
800
MAN UP/DWN
Run the motor manual from the menu
MOTOR UP / MOTOR DOWN
DMX ADDR
DMX start address
1-506
1
TAC RANGE
Tacho range
1-50,000
N/A
SPEED MAX
Maximum speed
500-3,500
3,500
SP MIN UP
Minimum speed UP
50-1,000
200
SP MIN DWN
Minimum speed DWN
50-1,000
200
E STOP
Enable/disable emergency stop
ON/OFF
OFF
MAN SPEED and MAN UP/DWN are used for manual control of the motor.
Detailed explanation of parameters
MAN SPEED
Speed for manual driving
Range
200-2,500
MAN SPEED sets the speed for manual driving the motor
MAN UP/DWN
Manually driving the motor
MAN UP/DWN is used for manual control of the motor.
Pressing the UP button, makes the wire run up. Pressing the DOWN button, makes the
wire run down, unless the limit switch is activated.
The winch will stop if the Emergency Switch is activated.
DMX ADDR
DMX start address
Range
1-506
DMX start address defines which DMX address the Winch 50 reacts on.
The Winch 50 uses minimum 6 DMX channels.
TAC RANGE
Tacho range
Range
1-50,000
The tacho range is setting the maximum range of the Winch
SPEED MAX
Maximum speed
Range
500-3,500
SPEED MAX sets the maximum speed.
If set to 1000, the motor run at 1000 RPM when DMX speed is set to full. SPEED MAX can
be used to lower the maximum speed, if desired.
SP MIN UP
Minimum speed up
Range
50-1,000
The motor minimum speed, for the up direction.
The motor is allowed to run at different minimum speed for each direction; this is to
differentiate between different mechanical loads for up and down. See SP MIN DWN.
Set this value to a speed where the motor will still run up at full load.
SP MIN DWN
Minimum speed down
Range
50-1,000
The motor minimum speed, for the down direction.
The motor is allowed to run at different minimum speed for each direction, this is to
differentiate between different mechanical loads for up and down, see SP MIN UP.
Set this value to a speed where the motor will still run down at full load.
E STOP
Enable/disable emergency stop
Range
ON / OFF
This enables/disables the emergency stop from the software. However, to get the full
functionality of the emergency stop a wire has to be plugged in inside the winch. See
section on how to change the wire setting for more details.
Summary of Contents for Winch 50 Double