JENS JUULS VEJ 1, 8260, VIBY, DENMARK
WWW.WAHLBERG.DK
TELEPHONE: +45 86 18 14 20
380.805.002
6
DATE: 2021-03-25
Menu navigation
By holding both up and down you will enter and exit the menu. Change any menu value
by pressing ENT and adjust the value accordingly. Save the value by holding ENT or
cancel by pressing ESC.
Adjustable menu parameters
Menu
Description
Range
Default
MAN SPEED
Speed for manually driving the device from menu.
0%-100%
100%
MAN UP/DWN
Run the motor manually from the menu.
MOTOR UP / MOTOR DOWN
DMX ADDRESS
DMX start address.
1-506
1
RANGE
Tacho range. Length of the entire track.
1-50,000
TRACK
RAMP TIME
Acceleration time from stop to max speed in seconds.
Increase this for slower more fluid motion.
0.1s-10.0s
1.0 s
MAX SPEED
Maximum movement speed. Maximum speed is also set by
channel 3.
10%-100%
100%
MIN SPEED
Minimum movement speed. Increase this if under heavy
load.
0%-100%
0%
AUTO RESET
Reset procedure after power up.
NONE: it will remember its position when shut down.
UP/DOWN: It will reset towards the desired limit switch.
NONE/UP/
DOWN
NONE
LED STATUS
Turn off LEDs during the show.
ON/OFF
ON
ADV MENU
Advanced menu. (Shows menu below)
ON/OFF
OFF
ORINTATION
Choose orientation of manipulator.
HORIZ: Horizontal movement
V.BOT: Vertical movement with motor box in the bottom.
V.TOP: Vertical movement with motor box in the top
HORIZ/V.BOT
/V.TOP
HORIZ
OVERLOAD
Set limit for electrical overload.
100
900
MEASURE DIS
Calibrates track length (done by factory)
Set to ON and reboot device to recalibrate track length.
ON/OFF
OFF
CH4 REENABL
If set OFF channel 4 does not have to be reenabled on start-
up
ON / OFF
ON
FACTORY RES
Reset all variables to factory default.
ON/OFF
OFF
MAN SPEED and MAN UP/DWN are used to manually control the motor without DMX.