Menu navigation 

By holding both up and down you will enter and exit the menu. Change any menu value 

by  pressing  ENT  and  adjust  the  value  accordingly.  Save  the  value  by  holding  ENT  or 

cancel by pressing ESC. 

Adjustable menu parameters 

Menu 

Description  

Range 

Default 

MAN SPEED 

Speed for manually driving the device from menu. 

0%-100% 

100% 

MAN UP/DWN 

Run the motor manually from the menu. 

MOTOR UP / MOTOR DOWN 

DMX ADDRESS 

DMX start address.  

1-506 

RANGE 

Tacho range. Length of the entire track. 

1-50,000 

TRACK 

RAMP TIME 

Acceleration time from stop to max speed in seconds. 
Increase this for slower more fluid motion. 

0.1s-10.0s 

1.0 s 

MAX SPEED 

Maximum  movement  speed.  Maximum  speed  is  also  set  by 
channel 3. 

10%-100% 

100% 

MIN SPEED 

Minimum  movement  speed.  Increase  this  if  under  heavy 
load. 

0%-100% 

0% 

AUTO RESET 

Reset procedure after power up.  
NONE: it will remember its position when shut down.  
UP/DOWN: It will reset towards the desired limit switch. 

NONE/UP/ 
DOWN 

NONE 

LED STATUS 

Turn off LEDs during the show. 

ON/OFF 

ON 

ADV MENU 

Advanced menu. (Shows menu below) 

ON/OFF 

OFF 

ORINTATION 

Choose orientation of manipulator. 
HORIZ: Horizontal movement 
V.BOT: Vertical movement with motor box in the bottom. 
V.TOP: Vertical movement with motor box in the top 

HORIZ/V.BOT 
/V.TOP 

HORIZ 

OVERLOAD 

Set limit for electrical overload. 

100 

900 

MEASURE DIS 

Calibrates track length (done by factory) 
Set to ON and reboot device to recalibrate track length. 

ON/OFF 

OFF 

CH4 REENABL 

If set OFF channel 4 does not have to be reenabled on start-
up 

ON / OFF 

ON 

FACTORY RES 

Reset all variables to factory default. 

ON/OFF 

OFF 

 

 

 

 

MAN SPEED and MAN UP/DWN are used to manually control the motor without DMX.  

 