3.4.7 Menu Operation and Functions
The menu structure is opened by pressing the menu button in the center of the directional buttons.
Figure 15: Menu Button
There are four sub-menus, which contain the functions listed in Table 1.
Measurement Settings
Camera Settings
Image Browser
Clock/Calendar
Emissivity
Color Palette
View
Year
Reflected Temperature
Auto Power
Delete
Month
Spot X
Factory Settings
Day
Temperature Units
Image Only
Hour
Area
B - C
Minute
Cursor Reset
Date Format
Time Format
Table 1:Menu Functions
The menu functions are selected by moving the highlighted cursor using the up and down directional buttons.
Menu items are edited using hot buttons 2 & 3 which are labeled and —. Hot button 1 is always
available to take you “back” one menu sub-level, while Hot button 4 is always available to “exit” the menus
completely. Figure 16 shows an example screenshot form the Measurement Settings menu, with the highlighted
cursor on the emissivity adjustor.
3.4.7.1
Measurement Settings
Figure 16: Menu Operation
Emissivity – The user can select the emissivity for the material being imaged. To achieve
correct temperature measurement the emissivity value must be set correctly. An emissivity table is included in
Section 6.
NOTE
: Caution should be observed in using the emissivity control – the user should explore the effect on
the observed temperature of an object when different emissivities are selected. Low values of
emissivity should be used only with extreme caution as large errors in temperature readings may be
obtained with only small errors in emissivity. Care should also be taken to avoid reflections from
hot/cold objects in the vicinity.