Failure guide

Complaint

Cause

Solution

Connections water

The safety unit hoses do not fit

The swivels of the hoses are too short

Get a different inlet set or different hoses

There is a white substance in the water

There is too much scale deposit in the tank

Disassemble and drain

There is a grey or brown substance in the water

The magnesium anode has dissolved

Contact the party that supplied  

the device originally  

within the warranty period *

Water leakage

Connections on the device have not  

been tightened sufficiently

Tighten

Sealing rings between hoses and  

device are missing

Add rings

Sealing rings between hoses and  

device are defective

Replace rings

Tank is leaking

Contact the supplier of the device *

Connection between tank and  

heating element is leaking

Contact the supplier of the device *

Safety unit is not properly attached

Tighten

Safety unit is ejecting water

Mount discharge of safety unit

No water

Main valve closed

Open Main valve

Stop valves closed

Open stop valves

Stop valve safety unit closed

Open stop valve

No hot water

Plug is not connected

Connect plug

Thermostat button not at the  

right position

Turn the thermostat button further

Heating element defective

Contact the supplier of the device *

Scale deposits in the flow regulator

De-scale the flow regulator

Water is too hot

Thermostat set too high

Set thermostat lower

There is too little water coming from the tap

Water pressure too low

Further open main/stop valves

There is steam coming out of the hot water tap

Thermostat and safeguard defective

Contact the supplier of the device *

The device makes boiling noises

Too much scale deposit in the device

Disassemble and drain

After installation, the tap makes bubbling noises

There is air in the pipes

Properly open and vent both valves 

 

(stop valve, kitchen tap)

Electricity

The fuses are blown

Too many appliances on 1 group

Try a different group

The earth leakage circuit breaker is activated

There is a short-circuit in  

the electrical wiring

Contact the supplier of the device *

Short-circuit

There is a short-circuit in the element

Contact the purchase address

There is a short-circuit in the thermostat

Contact the purchase address

The “ON“ lamp does not light

Plug is not connected

Connect plug

No water in the device and safety  

power interrupter is activated

This work may only be carried out by 

professionals: Pull out the plug and allow the 

device to cool down for 20 minutes. 

Disassemble the panel on the front side. The 

reset thermal switch is on the middle seen 

from the front. Press the reset button. 

Assemble the panel.  

Main power interrupted

Check in group box

Lamp is defective

Replace lamp

The “HEATING“ lamp does not light

Thermostat is off 

Turn the button further

The device is already at temperature

Do nothing

Summary of Contents for UTS15

Page 1: ...stabelle Garantiebedingungen GB 15 litre pressure boiler User manual Trouble shooting Conditions of Guarantee NL 15 liter drukboiler Gebruiksaanwijzing Storingswijzer Garantiebepalingen F Chauffe eau...

Page 2: ...2 UTS 15 A B option C D E N L Q Q Heating Element Heating Indicator light Thermal Cut Out Thermostat Power Indicator Brown Blue Yellow Green 11 5 3 7 4 10 1 2 6 9 8 Reset...

Page 3: ...beiten am Ger t zum Beispiel Beseitigung von Kalk und Wasserstein ablagerungen sollen ausschlie lich von autorisiertem Fach personal durchgef hrt werden Die geltenden Vorschriften DVGW Technische Rich...

Page 4: ...omagnetischen Vertr glichkeit EMV 2011 65 EC RoHS II 2009 125 EC Ecodesign Das Ger t entspricht auch die folgenden harmonisierten EU Normen EN 60335 1 2012 A11 2012 EN 60335 2 21 2003 A1 2005 A2 2008...

Page 5: ...zeige leuchtet wenn das Ger t aufheizt 10 Anode 11 Stecker Option Montage an der Wand Abbildung B Das Ger t muss an einer stabilen und massiven Wand montiert werden Die Wand muss mindestens das Gesamt...

Page 6: ...erden Gefahr durch besch digte Spannungsversorgungskabel ver meiden Bei Besch digung muss das Ger t vom Hersteller oder dessen Kundendienst oder gleichermassen qualifizier ten Person ersetzt werden St...

Page 7: ...uck 0 1MPa Maximal zul ssiger Druck 0 5MPa Abstand zwischen Rohrleitungen Wand 115mm Nennspannung 1 N PE 230V Frequenz 50Hz Nennleistung 1500 W Nominalvolumen 15L Kabelma 3x 1 0mm Schutzklasse I IP Sc...

Page 8: ...en wird Nachheizen Temperaturwahl OFF HIGH LOW HEATING POWER Schalten Sie den Speicher mit dem Ein Aus Knopf ein Die Lampe Power leuchtet auf Stellen Sie die gew nschte Temperatur ein indem Sie den li...

Page 9: ...asserleitungs netz abgekoppelt werden kann Das Entlastungsventil ist mit einem Ablassschlauch zum Abf hren des Expansionswas sers vom Ger t in die Kanalisation versehen Zum nachhaltigen Schutz vor Kor...

Page 10: ...nicht als Trinkwasser Nach l ngerer Abschaltung des Ger tes wie z B W hrend des Urlaubs soll das Ger t vor der Wiederinbetriebnahme vollst ndig bis auf die Maximaltemperatur aufgeheizt werden Es ist...

Page 11: ...tieleistungen bewirken we der eine Verl ngerung der Garantieperiode noch setzen sie eine neue Garantiefrist in Lauf Geltendma chung Das fehlerhafte Produkt zusammen mit der Kaufquittung an die Verkauf...

Page 12: ...t kein Wasser aus der Armatur Es kommt kein warmes Wasser aus der Armatur Das Wasser ist zu hei Es kommt zu wenig Wasser aus der Armatur Aus der Warmwasserarmatur tritt Dampf aus Das Ger t macht Kochg...

Page 13: ...entkalken Thermostatknopf zu hoch eingestellt Thermostatknopf auf eine niedriger Position drehen Wasserdruck zu niedrig Haupt Absperrventil weiter ffnen Thermostat und Sicherung defekt Nehmen Sie mit...

Page 14: ...le the removal of limestone and water scale deposits may only be carried out by duly authorised technical staff The applicable regulations and regional requirements must always be duly observed This d...

Page 15: ...s EN 60335 1 2012 A11 2012 EN 60335 2 21 2003 A1 2005 A2 2008 EN 62233 2008 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2014 EN 61000 3 3 2013 Wahlbach Gildestraat 13...

Page 16: ...nt on the wall Figure B The appliance must be fitted on a stable and solid wall The wall must be able to at least bear the total weight of a full boiler Determine a suitable place for the boiler Mount...

Page 17: ...ervice department or by an equiv alently qualified person Ensure that the addition of this device will not overload the fuse protection in your mains Internal modifications to the product may cause pr...

Page 18: ...Dimensions 388x388x331 mm Water connection G1 2 Daily electricity consumption Qelec 3 068 KWh Load profile XXS Sound power level LWA 15 dB Energy efficiency wh3 29 50 3 USER INSTRUCTIONS The device mu...

Page 19: ...scale build up and heat loss are much lower than at higher tempera tures As the water that is used for washing the dishes has a temperature of approximately 45 to 50 C cold water has to be mixed in t...

Page 20: ...nized fitter every 2 years Check the functioning of the inlet combination by turning the large knob on the inlet combination once a year allowing water to flow out and closing it immediately This will...

Page 21: ...whether the fuse of the device group is still working For all other failures please consult the failure guide If the device no longer works because it was connected without being filled with water fir...

Page 22: ...Water leakage No water No hot water Water is too hot There is too little water coming from the tap There is steam coming out of the hot water tap The device makes boiling noises After installation the...

Page 23: ...he supplier of the device Scale deposits in the flow regulator De scale the flow regulator Thermostat set too high Set thermostat lower Water pressure too low Further open main stop valves Thermostat...

Page 24: ...s provided shall neither prolong the warranty period nor initiate a new warranty period Claims The defective product should be sent together with the proof of purchase to the place of purchase Wahlbac...

Page 25: ...en Alle reparatie en onderhoudswerk zaamheden aan of in het apparaat zoals kalkverwijdering dienen te worden uitgevoerd door een gekwalificeerd ser vice en onderhoudsbedrijf De lokaal geldende richtli...

Page 26: ...mt met de volgende Europese geharmoniseerde normen EN 60335 1 2012 A11 2012 EN 60335 2 21 2003 A1 2005 A2 2008 EN 62233 2008 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3...

Page 27: ...d aan een stabiele en massieve wand De wand dient minimaal het totale gewicht van een gevulde boiler te kunnen dragen Bepaal een geschikte plaats voor de boiler Plaats de montagestrip aan de muur en p...

Page 28: ...beschadiging moet het apparaat door de fabrikant zijn klantenservice of een gelijkwaardig gekwalifi ceerde persoon worden vervangen Vergewis u ervan dat door toevoeging van het apparaat de gebruikte...

Page 29: ...erdruk 0 5MPa Afstand tussen aansluiting muur 115mm Elektrische aansluiting 1 N PE 230V Frequentie 50Hz Nominaal vermogen 1500 W Nominale inhoud 15L Kabelmaat 3x 1 0mm Beschermingsklasse I IP bescherm...

Page 30: ...mingselement zal automatisch afslaan zodra de wa tertemperatuur het ingestelde punt heeft bereikt Het apparaat zal het water weer op nieuw gaan opwarmen zodra de watertemperatuur weer onder het ingest...

Page 31: ...oerleiding kan stromen met een ontlastventiel dat de druk in het apparaat begrenst tot maximaal 8 bar en een stopkraan voor de keer klep voor het af kunnen koppelen van het apparaat van het waterleidi...

Page 32: ...rmd water niet om te drinken Bij langdurige uitschakeling van het apparaat bijvoorbeeld i v m vakantie dient u het apparaat v r het eerste gebruik volledig tot de maximale temperatuur op te warmen Het...

Page 33: ...rlenging van de garantieperiode en start ook geen nieuwe garan tieperiode Claimen Breng het defecte apparaat samen met het aankoopbewijs terug naar het verkooppunt Wahlbach is niet aansprakelijk voor...

Page 34: ...n het water Lekkage van water Er komt geen water Er komt geen warm water Water is te heet Er komt te weinig warm water uit de kraan Er komt stoom uit de warmwaterkraan Het apparaat maakt kookgeluiden...

Page 35: ...kapot Neem contact op met het aankoopadres Kalk in de straalregelaar Ontkalk de straalregelaar Thermostaat te hoog ingesteld Thermostaatknop lager zetten Waterdruk te laag Hoofd stopkranen verder ope...

Page 36: ...ux d entretien ou de r para tion effectuer dans ou sur l appareil comme le d tar trage doivent tre ex cut s par un service qualifi et une entreprise d entretien Les directives en vigueur localement do...

Page 37: ...e compatibilit lectromagn tique 2011 65 EC RoHS II 2009 125 EC Eco design Le produit est aussi conforme aux normes UE harmonis es suivantes EN 60335 1 2012 A11 2012 EN 60335 2 21 2003 A1 2005 A2 2008...

Page 38: ...que l appareil est reli au r seau lectrique 9 Indication lorsque l appareil chauffe 10 Anode 11 Prise Optionnel Placement sur le mur Illustration B L appareil doit tre mont sur un mur stable et massif...

Page 39: ...li des c bles lectriques endomma g s Si un c ble est endommag l appareil doit tre rem plac par le fabricant son service la client le ou une per sonne de qualification quivalente Assurez vous que la p...

Page 40: ...31 mm Raccordement d eau G1 2 Consommation journali re d lectricit Qelec 3 068 KWh Profil de soutirage XXS Niveau de puissance acoustique LWA 15 dB Efficacit nerg tique wh3 29 50 3 INSTRUCTIONS D UTIL...

Page 41: ...on de chaleur vers l ext rieur ainsi que le d p t de calcaire sont inf rieurs aux valeurs atteintes en cas d utilisation d appareil dans une position sup rieure Le chauffage de l eau implique une augm...

Page 42: ...urit jusqu ce que de l eau s coule puis refermez le imm diatement Cette manipulation permet d viter un blocage de la sou pape dans le groupe de s curit V rifiez galement que l vacuation n est pas obst...

Page 43: ...enfich e dans la prise et si le fusible du groupe de l appareil fonctionne bien Pour toutes les autres dysfonctionnements s il vous pla t consulter la guide de perturbation Si l appareil ne fonctionne...

Page 44: ...s L J f T T Il n y a pas d eau R R R Il n y a pas d eau chaude I L B c L L eau trop chaude T Robinet donne pas assez d eau chaude C Robinet d eau chaude donne de la vapeur T L appareil fait un son d b...

Page 45: ...z un peu plus le bouton du thermostat L l ment chauffage ne fonctionne pas Contactez le point de vente Thermostat positionn trop lev Tournez le bouton du thermostat en bas Charge d eau trop bas Ouvrez...

Page 46: ...antie fournies n en tra nent aucune prolongation de la p riode de garantie et une nouvelle p riode de garantie ne commence pas courir Conversion en valable Ramener le produit d fectueux ainsi que la f...

Page 47: ...47...

Page 48: ...WB V1 2016 01 WWW WAHLBACH COM...

Reviews: