178 •
Reference Commands for Move Mode
Setpoint
commands
WAGO-I/O-SYSTEM
750
I/O
Modules
3.2.4.1.14
SET_ACC_PARAM_UP (0x23)
Set the Acc_ParamUp parameter for acceleration; valid as of the next
positioning process.
The function for the acceleration parameter as a function of the set
acceleration modification is shown in the following table.
Acceleration modification
(SET_ACC_MODE
ACC_M)
Acceleration parameter
Acc_ParamUp
none
Time constant for acceleration increase
with linear or sin
2
*t acceleration
constant acceleration period Acceleration
time
constant acceleration path
Acceleration path
Acceleration parameter range: 1 … 16777215.
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MB0
0x40
MB1 T
-
MB2
0x23
MB3
Acceleration parameter (LSB)
MB4 Acceleration
parameter
MB5
Acceleration parameter (MSB)
Response
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MB0
0x40
MB1 T
Return
Code
MB2
0x23
MB3 Reserved
MB4 Reserved
MB5 Reserved