22 Device Description
WAGO-I/O-SYSTEM 750 XTR
750-483/040-000 2AI 0-30 VDC Diff XTR
Manual
Version 1.1.0
3.6.3
Inputs
Table 8: Technical Data – Inputs
Number of inputs
2
Connection types
Differential measurement inputs
electrically isolated
Input filter
Low pass 1
st
order, f
G
= 5 kHz
Signal voltage
0 … 30 V
Measured value acquisition
Time synchronous within the
I/O module
Operating mode
Continuously sampling (default)
Value of an LSB (bit 1)
(least significant bit)
1.8 mV
Internal resistance
typ.
1
MΩ
Resolution of the A/D converter
14 bits
Resolution of measured value
14 bits plus sign bit
Monotonicity without error code
Yes
Measuring error at 25 °C
≤ ±0.05
% of full scale value
Temperature coefficient
< ±0.01
% /K of full scale value
Measuring errors
≤ ±0.4
% over the entire temperature
range
≤ ±0.1
% of upper-range value
(non-linearity)
Conversion method
SAR (Successive Approximation
Register)
Crosstalk attenuation
≥
80 dB
Sampling repetition time
1 ms
Sampling delay (module)
1 ms
Sampling delay (channel/channel)
≤ 1
µs
Sampling duration
≤ 5
µs
Protection
RC element
Admissible continuous overload
±60
VDC
Dielectric strength
1 kV DC channel/channel or
channel/system
Diagnostics
Measurement range underrange/
overrange
Signaling with diagnostics
Status byte and LED
3.6.4
Communication
Table 9: Technical Data – Communication
Data width
2 × 16 bits data
2 × 8 bits control/status (optional)