DeviceNet • 93
Configuration / Parametering with the Object Model
WAGO-I/O-SYSTEM 750
DeviceNet
RELEASE_
PIO
1: Process the coupler fault reaction
25 specific
get/set
BK_DO_FA
ULT_REAC
TION_ON_
RELEASE_
COS
USINT
Defines the behavior after de allocation the
Change of State and Cyclic I/O Connection
0: (default) do nothing
1: Process the coupler fault reaction
26 specific
get/set
BK_DO_FA
ULT_REAC
TION_ON_
RELEASE_
ST
USINT
Defines the behavior after de allocation the
strobed Connection
0: (default) do nothing
1: Process the coupler fault reaction
40 specific
get/set
BK_static_
ana-
log_digital_i
nput_mappi
ng
UINT
Defines how to calculate the values for the
number of analog and digital input bits.
0000: All bits are digital
0016: One word is analog remaining bits are
digital
0032: Two words are analog remaining bits
are digital
...
0xFFFF: All bits are handled like module type
(default)
41 specific
get/set
BK_static_
ana-
log_digital_
out-
put_mappin
g
UINT
Defines how to calculate the values for the
number of analog and digital input bits.
0000: All bits are digital
0016: One word is analog remaining bits are
digital
0032: Two words are analog remaining bits
are digital
...
0xFFFF: All bits are handled like module type
(default)
(If the number of analog bits exceeds the size
of the process image all bits are mapped to
analog bits.
42 specific
get/set
BK_specific
_coupler_b
ehavior
UINT
Defines the couplers functionality.
0xFFFF: All possible functions are enabled.
(resetting a bit to 0 disables the assigned
functionality).
It is only possible to reduce the functionality.
Resetting to „1“ is ignored.
43 specific
get/set
BK_revisio
n_setting
UINT
Defines the couplers major and minor revision
attribute.
0xFFFF: The major and minor revison Attrib-
utes are set by the firmware.
(This is the default behavior).
0x??00: The minor revison is set to 0.
0x03??: The mjor revison is set to 3.
All other values are valid to.
45 specific
get BK_LED_ER
R_CODE
UINT
Defines the Error Code, displayed by the
blink code of the I/O LED.
46 specific
get BK_LED_ER
R_ARG
UINT
Defines the Error Argument, displayed by the
blink code of the I/O LED.
47 specific
get BK_DIAG_V
ALUE
UINT
Defines the Diagnostic information, supplied
by the IO Module. This attribute must be read
out before attribute 6 of this class. Only if
attribute 6 contains valid data, it contains also
valid data.
48 specific
get/set
BK_FIXED_P
ROD_SIZE
USIN
T
Fixed width of the ProduceConnectionSize
(input data) 0xFFFF(default): ProduceCon-
nectionSize corresponds to the data width of
the connected input modules 0 – 32 (
PI_LIMIT ): Fixed width of the ProduceCon-
nectionSize, independent of the input mod-
ules. PI_LIMIT – 0xFFFE: These values
These values cannot be set and led to fault
messages. The adjusted value become only on
valid with next switching.
49 specific
get/set
BK_FIXED_C
ONS_SIZE
USIN
T
Fixed width of the ConsumedConnectionSize
(output data)