19. Rectifying errors when working with the spray lance
Problem
Cause
Remedy
No coating material
emerges from the
nozzle
•
Nozzle clogged
•
Material volume setting
turned too far to the left
•
When trigger is not
completely pushed through,
the feed pump is not
switched on
•
Control hose blocked or
damaged
•
Container empty
•
Suction hose is blocked
•
The suction hose is
disconnected from the basic
device
•
The suction hose is not in
the paint
•
Pull wire is disconnected or
not tight enough
•
The material hose is
disconnected from the spray
head or basic device
•
Pump is defect
➞
Clean
➞
Turn to the right
➞
Push trigger through
completely
➞
Clean or replace
➞
New paint container
➞
Clean suction hose
➞
Reattach the suction hose
➞
Immerse the suction hose
➞
Connect and tighten the
pull wire
➞
Reattach the material hose
➞
Please contact Wagner
Service
Coating material
drips from the
nozzle
•
Coating material assembly
at air cap, nozzle or needle
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Pull wire is too tight
➞
Clean
➞
Union nut tighten
➞
Change
➞
Change
➞
Reduce tension
Atomisation too
coarse
•
Material volume too large
Material volume setting
turned too far to the right
•
Nozzle contaminated
•
Viscosity of coating material
too high
•
Air filter heavily soiled
•
At high quantity of material,
narrow spray jet selected
(red)
➞
Turn the material volume
setting to the left
➞
Clean
➞
Dilute further
➞
Change
➞
Switch to wide spray jet
(green)