4
StARtuP
4.1
unIt WItH SuctIOn SyStem
1. Unscrew the dust protective cap (Item 1).
2. Ensure that the sealing surfaces of the connections are
clean.
Ensure that the red inlet (2) is inserted in the coating ma-
terial inlet (5).
3. If using the suction system
Use the enclosed 41 mm wrench to screw the union nut
(3) at the suction hose (4) onto the coating material inlet
(5) and tighten it.
If using the upper container (accessories)
Screw container adapter (12) to coating substance inlet
(5) and fasten finger-tight. Place upper container (9) on
container adapter (12) and align. Place return hose (7) in
upper container.
4. Screw the union nut (6) at the return hose (7) to the con-
nection (8) (22mm).
4.2
HIGH PReSSuRe HOSe And SPRAy Gun
A special adapter is required for operation
with several guns (see accessories). Several
adapters can be connected together, so that
two additional guns can be used per adapter.
1. Screw adapter for multiple-gun operation to hose con-
nection (if required).
2. Screw the high pressure hose (10) onto the hose connec-
tion or the adapter.
Unused connections on the adapter must be
sealed with the protective caps provided.
Only connect as many hoses as will be used.
All connected hoses are pressurised!
3. Screw the spray gun (11) onto the high pressure hose
4. Tighten all union nuts on high pressure hose so that no
coating material can escape.
5. Screw the tip holder with the selected tip onto the spray
gun, align tip and tighten union nut.
When unscrewing the high pressure hose,
hold firmly on the hose connection with a
22mm wrench.