24
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2354920
SPRINT XE
5.3
OPERATION OF THE CONTROL UNIT
P_01743
EPG
SPRINT X
2x
2x
0
%
100
%
kV
80
60
40
20
100
Tri
Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
μA
28
27
30
29
31 32
37 35
24
34
36
33
1
2
3
4
20 22
23 18 13
19
21
12
8
11
7
10
6
9
25
26
16
17
15
14
5
1
Illuminated display: "High voltage"
– Lights up green
– Display range: 0-100 kV
– Resolution 10 kV
– Single LED display: Nominal voltage
– Bar display: Working voltage
2
Illuminated display: "Corona or Tribo Current"
– Lights up green
Tribo scale:
– When a Tribo gun is connected and selected
– Bar display: When powder feed is activated
– Display range: 0-5 μA
Resolution 0.5 μA
Corona scale:
– When a Corona gun is connected and selected
– Display and adjusting range: 0 [5]–120 μA,
0 [5]–20 μA resolution 5 μA
20-40 μA resolution 10 μA
40-120 μA resolution 20 μA
– Single LED display: "Trigger Point of Current Limitation"
– Bar display: Corona current