ProSpray 26
35
GB
9. Close the relief valve, valve position SPRAY (
p
spray).
10. Pull the trigger of the spray gun.
11. Pump the remaining cleaning agent into an open container
until the unit is empty.
12. Switch the unit OFF.
8.1
Cleaning unit from outside
Wipe down unit externally with a cloth which has been
immersed in a suitable cleaning agent.
8.2
Suction filter
1. Screw off the filter (Fig. 9) from suction pipe.
2. Clean or replace the filter.
Carry out cleaning with a hard brush and an appropriate
cleaning agent.
8.3 Cleaning the high-pressure filter
Clean the filter cartridge regularly.
A soiled or clogged high-pressure filter can cause a poor spray
pattern or a clogged tip.
1. Turn the pressure regulator knob into the black zone until it
stops (no pressure).
2. Open the relief valve, valve position PRIME
(
k
circulation).
3. Switch the unit OFF.
4. Unscrew the filter housing (Fig. 10, Item 1). with a strap
wrench.
5. Pull the filter cartridge (2) from the bearing spring (3).
6. Clean all the parts with the corresponding cleaning agent.
If necessary, replace the filter cartridge.
7. Check the O-ring (4), replace it if necessary.
Unplug the power plug from the outlet.
Danger
A clean suction filter always guarantees
maximum feed quantity, constant spraying
pressure and problem-free functioning of the
unit.
i
Danger of short circult through panetrating
water!
Never spray down the unit with
high-pressure or high-pressure steam
cleaners.
Danger
First of all pull out mains plug from socket.
Danger
Cleaning the unit (shutting down)
8. Place the bearing ring (5) against the bearing spring (3).
Slide the filter cartridge (2) over the bearing spring.
9. Screw in the filter housing (1) and tighten it as far as
possible with the strap wrench.
8.4 Cleaning Airless spray gun
1. Rinse Airless spray gun with an appropriate cleaning
agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the Airless spray gun.
Intake filter in Airless spray gun
Disassembly (Fig. 11)
1. Pull protective guard (1) forward vigorously.
2. Screw grip (2) out of the gun housing. Remove intake filter
(3).
3. Intake filter congested or defective – replace.
Assembly
1. Place intake filter (3) with the long cone into the gun
housing.
2. Screw in grip (2) into the gun housing and tighten.
3. Slot in protective guard (1).
W
arn
ing
:
ke
ep
cl
ea
r
of
tip
25
0 b
ar
ma
x.3
60
0 p
si
3
2
1
4
3
2
1
5