Start
up
6
0241891
– PI-P1 / PI-F1
08/2008
2. Start
up
2.1
Preparing the powder injector
Caution
The powder injector
must
be grounded to prevent static charging!
In this case, you must use the Wagner Special hose!
2.1.1 Connecting the powder hose
Push the powder hose
2
onto the collector-nozzle
1
until it is firmly fixed.
It is
recommended
that
special hose
is used with an inner diameter of 11 or 12 mm, as
illustrated in Chapter
5.4
"
Special accessories
". This hose is equipped with an integrated
grounding wire, which contributes greatly to preventing powder charging.
1
2
PI_01
Conductive collector-nozzle
Powder hose with grounding wire
Conductive nut
2.1.2 Grounding
The powder injector
must
be fitted with a grounding cable in application modes.
The grounding cable
must
be connected
to the rear side of the control unit or to
the system ground:
M5 threaded hole with 4 mm
core hole diameter
for grounding cable
See chapter
5.4
"
Special accessories
"
for article numbers.
Use only conductive O-ring.
LA_02