PEM-CG3
Start up and Working
3.
Working with the spray guns
3.1
Starting up the spray gun
•
Switch on the control unit, actuate the trigger on the spray gun and set the compressed air
supply at
29 psi
(2 bar).
•
Adjust the high voltage at the control unit.
•
Check at the control unit whether the atomizing air is opened on actuating the trigger. As a
result the deflector cone remains free from powder deposits and the cascade chamber is
flushed.
•
Fill the powder container to
max. 75%
of its capacity with powder, but
do not
close the
cup yet.
K
L
Fluid air
Feed air
•
Open the fluid air supply slowly with the
green
setting
knob
L
until the powder is fluidized.
•
The powder should be simmering slightly.
•
Close the powder container tightly.
•
Hold the manual spray gun in the spray booth and
actuate the trigger on the manual spray gun.
•
Open the
red
setting knob
K
to provide a feed air sup-
ply relative to the desired powder throughput.
3.2
Switching off the spray gun
Hint
On each interruption to work, the spray gun should be blown through (purged) and
powder residue removed. In this way
powder deposits
and a
surge
the next time the
spray gun is switched on can be largely avoided.
H
J
X
X
K
L
Fluid air
Feed air
•
Switch off the high voltage generator
at the control unit.
•
Unscrew the powder container
H
from the adapter
J
.
•
Close the fluid air supply with the
green
setting knob
L
.
•
Open the feed air supply wide with
the
red
setting knob
K
.
•
Hold the manual spray gun in the
spray booth, actuate the trigger, so
that the spray gun is blown free of
powder.
•
Switch off the control unit and
secure it against being switched on
unintentionally.
0351713 10
03/2003
Summary of Contents for PEM-CG3
Page 23: ......