8
English
Title
1. Pull the return tube
(a)
from the hopper and hold it over a
waste container.
4. Remove hopper lid. Fill your hopper with the material you
plan to spray.
Do not exceed 2 1/2 gallons (b).
5. Switch your unit ON once more and make sure that
material is flowing from the return tube
(c)
. Turn pump
OFF and replace the hopper lid.
l
(c)
(b)
Any fluids remaining in the pump and the return tube will
flow out of the return tube. Let the pump run until no
fluid is coming from the return tube.
(a)
3. Switch the pump to OFF. Remove the return tube from
the waste container and insert it into the notch in the
hopper lid
(a)
.
2. Turn the PRIME/SPRAY knob to PRIME.
Plug in the sprayer.
Turn the ON/OFF switch to ON (l).
(a)
Purging and Priming the Sprayer
All new units are performance-tested at the factory and are shipped with test fluid in the fluid section to prevent
corrosion during shipment and storage. If you have already used your pump, some water or solvent used in cleaning
may remain in the fluid section. Whether your sprayer is new or if you have already used it, this fluid must be purged
and thoroughly cleaned out of the system prior to use. Follow the steps below.
PRIME
PRIME
PRIME
l
If spray material does not flow from the return tube, the
inlet valve may be stuck. Follow these steps.
1. Shut the unit OFF and unplug.
2. Carefully remove the hopper. Clean the connecting areas
on the hopper and the unit.
3. Insert the inlet pusher tool
(d)
into the center of the inlet
valve area
(e)
. This should release the inlet valve and
allow spraying material to flow through the return tube.
4. Replace hopper and return tube and resume.
(d)
(e)