background image

 

10 

P20

GB

Handling the high-pressure hose 

Cleaning the unit (shutting down)

6. 

Handling the high-pressure hose

Avoid sharp bending or kinking of the high-pressure hose. The 

smallest bending radius amounts to about 20 cm.
Do not drive over the high-pressure hose. Protect against sharp 

objects and edges.

Danger of injury through leaking high-pressure 

hose. Replace any damaged high-pressure hose 

immediately.
Never repair defective high-pressure hoses yourself!

6.1 

High-pressure hose

The unit is equipped with a high-pressure hose specially suited for 

piston pumps.

i

Only use WAGNER original-high-pressure hoses in 

order to ensure functionality, safety and durability.

7. 

Interruption of work

  1.  Open the relief valve, valve position PRIME
 

  (

k

 circulation).

  2.  Switch the unit OFF.
  3.  Turn the pressure control knob counterclockwise to minimum 

pressure.

  4.  Pull the trigger of the spray gun in order to release the 

pressure from the high-pressure hose and spray gun.

  5.  Secure the spray gun, refer to the operating manual of the 

spray gun.

  6.  If a standard tip is to be cleaned, see Page 17, Section 12.2.
 

  If a non-standard tip is installed, proceed according to the 

relevant operating manual.

  7.  Depending on the model, leave the suction tube or the 

suction hose and return hose immersed in the coating 

material or swivel or immerse it into a corresponding cleaning 

agent.

Attention

If fast-drying or two-component coating material is 

used, ensure that the unit is rinsed with a suitable 

cleaning agent within the processing time.

8. 

Cleaning the unit (shutting down)

A clean state is the best method of ensuring operation without 

problems. After you have finished spraying, clean the unit. Under no 

circumstances may any remaining coating material dry and harden in 

the unit.
The cleaning agent used for cleaning (only with an igni tion point 

above 21 °C) must be suitable for the coating material used.
 

• 

Secure the spray gun, refer to the operating manual of the 

spray gun.

Clean and remove tip.
For a standard tip, refer to Page 17, Section 12.2.
If a non-standard tip is installed, proceed according to the relevant 

operating manual.
  1.  Remove suction hose from the coating material.

  2.  Close the relief valve, valve position SPRAY (

p

 spray).

  3.  Switch the unit ON.
  4.  Pull the trigger of the spray gun in order to pump the 

remaining coating material from the suction hose, high-

pressure hose and the spray gun into an open container.

Attention

The container must be earthed in case of coating 

materials which contain solvents.

Caution! Do not pump or spray into a container with 

a small opening (bunghole)!
Refer to the safety regulations.

  5.  Immerse suction hose with return hose into a container with a 

suitable cleaning agent.

  6.  Turn the pressure control knob counterclockwise to minimum 

pressure.

  7.  Open the relief valve, valve position PRIME 
 

  (

k

 circulation).

  8.  Pump a suitable cleaning agent in the circuit for a few 

minutes.

  9.  Close the relief valve, valve position SPRAY (

p

 spray).

  10.  Pull the trigger of the spray gun.
  11.  Pump the remaining cleaning agent into an open container 

until the unit is empty.

  12.  Switch the unit OFF.

8.1 

Cleaning unit from outside

First of all pull out mains plug from socket.

Attention

Danger of short circult through penetrating water!
Never spray down the unit with high-pressure or 

high-pressure steam cleaners.

Wipe down unit externally with a cloth which has been immersed in a 

suitable cleaning agent.

Summary of Contents for P20 0552488

Page 1: ...Edition 8 2012 0552 874B GB Operating manual Models 0552488 0552490 P20 Airless high pressure spraying unit...

Page 2: ...doctor about the coating material or solvent used The operating instructions state that the following points must always be observed before starting up 1 Faulty units must not be used 2 Secure WAGNER...

Page 3: ...10 7 Interruption of work 10 8 Cleaning the unit shutting down 10 8 1 Cleaning unit from outside 10 8 2 Suction filter 11 8 3 Cleaning Airless spray gun 11 Page 9 Remedy in case of faults 12 10 Servic...

Page 4: ...d in place All accessories must be rated at or above the maximum operating pressure range of the sprayer This includes spray tips guns extensions and hose NOTE TO PHYSICIAN Injection into the skin is...

Page 5: ...ay hoses are routed in such a manner to minimize slip trip and fall hazard Clean up all material and solvent spills immediately to prevent slip hazard ALWAYS follow the material manufacturer s instruc...

Page 6: ...d in Air bubbles disturb when spraying and can in fact lead to interruption of operation Viscosity With this unit it is possible to process highly viscous coating materials of up to around 20 000 MPa...

Page 7: ...Return hose 4 Suction hose 5 Frame 6 Drip cup 7 Power cord 8 Relief valve Lever position vertical PRIME k circulation Lever position horizontal SPRAY p 9 Pressure control knob 10 ON OFF switch 11 Circ...

Page 8: ...Fig 2 Item 4 3 Screw the spray gun 5 with the selected tip onto the high pressure hose 4 Tighten the union nuts at the high pressure hoses firmly so that coating material does not leak 5 1 4 2 3 5 Fil...

Page 9: ...rd Do not spray without the tip guard in place NEVER trigger the gun unless the tip is completely turned to either the spray or the unclog position ALWAYS engage the gun trigger lock before removing r...

Page 10: ...tion without problems After you have finished spraying clean the unit Under no circumstances may any remaining coating material dry and harden in the unit The cleaning agent used for cleaning only wit...

Page 11: ...an appropriate cleaning agent 2 Clean tip thoroughly with appropriate cleaning agent so that no coating material residue remains 3 Thoroughly clean the outside of the Airless spray gun Intake filter i...

Page 12: ...ng material which is to be sprayed 2 Pressure setting incorrect 3 Volume too low 4 Coating material viscosity too high 1 Pressure setting too low Measures for eliminating the malfunction 1 Check volta...

Page 13: ...repair work Unplug the power plug from the outlet 11 1 Relief valve 1 Use a drift punch of 2 mm to remove the grooved pin Fig 8 Item 1 from the relief valve handle 2 2 Remove the relief valve handle 2...

Page 14: ...and O ring 6 9 Clean all the parts with the corresponding cleaning agent Check the inlet valve housing 1 inlet valve seat 5 and inlet valve ball 4 for wear and replace the parts if necessary If the wo...

Page 15: ...tighten by hand 13 Push installation tool included with the replacement packings for the piston 3 from above onto the piston 14 Lubricate installation tool and piston 3 with machine grease 15 Guide p...

Page 16: ...m MB FB MB FB M F M F M F F F F F F 1 2 3 4 M F F WH6WH1 WH2 WH7 WH4 WH5 Red Red Blue Blue Brown black Blue white Brown black Blue white Motor EMI filter Microswitch Power cord Switch Capacitors Black...

Page 17: ...elief valve handle fully counterclockwise k Circulation 2 Switch off the gasoline engine 3 Dismount the tip from the spray gun 4 Place tip in an appropriate cleaning agent until all coating material r...

Page 18: ...8 295 0552 619 719 70 0 019 0 48 320 0552 719 819 80 0 019 0 48 400 0552 819 Mica paints 221 20 0 021 0 53 145 0552 221 Zinc dust paints 421 40 0 021 0 53 190 0552 421 Dispersions 521 50 0 021 0 53 24...

Page 19: ...0m Spraypack consisting of basic unit 2311659 Airless gun AG 14 NPS 1 4 incl Trade Tip 2 nozzler holder F thread and Trade Tip 2 Fine Finish 410 2311660 2311853 TempSpray H 226 ideal for dispersions m...

Page 20: ...20 P20 g Accessories illustration 3 1 5 7 9 2 4 6 8...

Page 21: ...ssure hoses 1 4 x 1 4 6 0034 950 Metex Reuse Reuse for pre filtering of coating material in vessel Place suction pipe in the reuse 0034 952 Sieve package 5 pcs for paint 0034 951 Sieve package 5 pcs f...

Page 22: ...29 1 2 20 21 24 23 22 25 26 27 28 13 14 15 16 17 18 19 6 3 4 10 11 12 5 8 3 32 34 35 36 38 37 33 31 4 9 7 g Main Assembly 0558 466 110V 20 Ft 800 741 120V 8 25 Ft BS4343 NEMA 5 15P 8 466 10V Ft 800 74...

Page 23: ...522 Knob housing 16 9822 522 Retaining ring 17 02712 Spring 18 0551 521 Plunger 19 Drive assembly 20 0509 218 Screw 4 21 0551 518 Face plate 22 0552 482A Fluid section assembly 23 0507 931 Cam base 2...

Page 24: ...24 P20 Spare parts list P20 24 25 26 1 2 3 4 5 7 6 8 11 9 12 14 13 15 16 17 18 19 20 21 22 23 10 g Fluid section...

Page 25: ...2 Upper cage 13 0551 263 Crush washer 14 0508 672 Outlet valve ball 15 0551 620 Outlet valve seat 16 13481 Outlet valve retainer 17 704 535 Bushing 18 0509 581 Inlet valve seal 19 0509 591 Lower ball...

Page 26: ...Description 1 806 100A Housing assembly includes item 9 2 0508 573 Thrust washer 3 0508 572 Gear crankshaft assembly 4 0509 121 2nd stage gear 5 0558 353A Motor assembly 6 9820 213 Washer 4 7 9800 341...

Page 27: ...5 g Motor Assembly Item Part No g Description 1 0522 100 Capacitor assembly 2 806 304 Fan shroud 2 3 704 322 Screw 2 4 806 308 Fan 5 9804 916 Screw 6 0551 543 Tie wrap 7 0558 353A Motor assembly incl...

Page 28: ...377 Cord holder 2 806 071 Leg left 3 9885 546 Plug 2 4 0551 527 Screw 5 0509 856 Nut 6 0290 234 Leg right 7 806 216 Tube clip 8 0551 434 Screw 9 0508 381 Drip cup 10 9805 230 Screw 11 9885 546 Plug 2...

Page 29: ...arts list P20 g Suction system Item Part No g Description 1 0551 706 Siphon hose 2 9850 638 Tie wrap 2 3 0551 707 Retun tube 4 0279 459 Clip 5 9871 105 O ring 2 6 9822 526 Clip 0551 705 Siphon tube as...

Page 30: ...lgora MB Italia Tel 39 039 625 021 Telefax 39 039 685 18 00 info wagnercolora com CH Wagner International AG Industriestrasse 22 9450 Altst tten Schweiz Tel 41 71 7 57 22 11 Telefax 41 71 7 57 22 22 w...

Page 31: ...duct is not to be disposed of together with household waste material but must be recycled in an environmentally friendly way Wagner or one of our dealers will take back your used Wagner waste electric...

Page 32: ...claims must be made immediately or at the latest within a period of 2 weeks The authorised specialist shop that delivered the device is entitled to accept guarantee claims Guarantee claims may also b...

Reviews: