background image

17 

Warranty 

 
 

Wagner Meters warrants this product against defects in material and workmanship for one (1) year from 
the date of purchase, subject to the following terms and conditions: 
 
“Wagner Meters’ liability under this warranty shall be limited, at Wagner Meters’ option, to the repair or 
replacement of this product or any part thereof which is demonstrated to be defective. To exercise this 
warranty, visit 

www.wagnerrepairs.com

  for instructions. This limited warranty does not apply if the 

product has been damaged by accident, negligent handling, misuse, alteration, damage during shipment, 
or improper service. Wagner Meters shall, in no event, be liable for any breach of warranty or defect in 
this product, which exceeds the amount of the purchase price of the product. Wagner Meters shall not be 
liable for incidental or consequential damages for the breach of any express or implied warranty with 
respect to this product or its calibration.” 
 
With proper care and maintenance, as recommended in the manual, the meter should stay in calibration; 
however, because Wagner Meters has no control over the manner in which the unit will be used, it makes 
no warranty that the meter will stay in calibration for any specific period of time. Wagner Meters 
recommends purchasing a calibration verification block or returning the unit to the factory for diagnostic 
checkup and recalibration on the anniversary date of purchase, each year the meter is in service. 
 

This warranty is in lieu of all other warranties, whether oral or written, express or implied. Any 
implied warranties, including implied warranties of merchantability and fitness for a particular 
purpose, are excluded. 

Agents and employees of Wagner Meters are not authorized to make 

modifications to this warranty or additional warranties binding on Wagner Meters. Accordingly, 
additional statements, whether oral or written, except written statements from an officer of Wagner 
Meters, do not constitute warranties and should not be relied upon by the customer. 
 
This warranty is personal to the customer purchasing the product from Wagner Meters and is not 
transferable. 
 

Repair Service

—In the event of damage or failure to your meter, contact Wagner Meters at 

www.wagnerrepairs.com

 or by phone for complete shipping and repair information.  

 
* If parts are unavailable to repair we reserve the right to replace the meter with an alternative model with 
equal or better accuracy and range 
 

Voice:      

(541) 582-0541 

Fax: 

    

(541) 582-4138 

 

 

 

Email:

 [email protected] 

 

Mail:   

Technical Services Department 

Wagner Meters 
326 Pine Grove Road 
Rogue River, OR 97537 

 

Your meter will be repaired, calibrated  
and returned promptly. 

 
 

Summary of Contents for L601-3

Page 1: ...Reference Calibrated for Douglas fir INSTRUCTIONS And Species Adjustment Tables Model L601 3 Hand Held Moisture Meter 1 800 634 9961...

Page 2: ...CTIONS 4 TAKING MEASUREMENTS 5 METER CALIBRATION 5 METER STORAGE 5 QUESTIONS ANSWERS 6 SPECIES ADJUSTMENT TABLE 11 SPECIFIC GRAVITY VS MOISTURE CONTENT 14 OTHER MATERIALS 15 ZERO ADJUSTING 16 WARRANTY...

Page 3: ...ness cross section method used when performing the ASTM D 4442 92 oven dry lab method This ASTM standard and its international counterparts is the standard to which all moisture meters for wood are co...

Page 4: ...ur species and the corresponding meter reading Example Your meter reading is 13 Figure1 Your species is Basswood American Locate your species in the tables provided Find the species in the appropriate...

Page 5: ...covered by the wood you are measuring If the sensing area is not completely covered your moisture reading will be inaccurate Additional meter corrections may be necessary if you are measuring Raft Wo...

Page 6: ...y companies use their hand held meters from Wagner Meters to read right through the plastic wrapping around the wood on new deliveries before they allow unloading 3 Where Readings are Taken Q Where is...

Page 7: ...n measure accurately with this hand held meter from Wagner Meters A Model L601 3 measures boards as narrow as 2 in width 6 Board Thickness Q What board thickness can I measure A Model L601 3 meters ar...

Page 8: ...ngth and breadth However using a hand held moisture meter from Wagner Meters you can quickly and easily scan 4x lumber on both sides 4 x 4 s on all four sides Then only the center 1 5 8 would be unmea...

Page 9: ...it does Note It s important on rough material to use some pressure and hold the meter down firmly against the wood Occasionally the measurement of exceptionally rough material may necessitate adding 1...

Page 10: ...e wood is to be used in construction as a stud for building the moisture content requirement could be 15 to 19 If the wood is to be glued and it is too dry it will not bond if it is too wet it will no...

Page 11: ...5 16 5 17 5 18 5 19 5 20 5 21 5 22 5 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 32 0 33 0 34 5 35 5 0 47 Cedar Eastern red cedar 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 16 5 17 5 18 5 19 5 20...

Page 12: ...2 5 23 5 24 5 0 50 Magnolia Southern 5 5 6 5 7 5 8 5 9 5 10 5 11 5 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 19 5 20 5 21 5 22 5 23 5 24 5 25 5 26 5 27 0 28 0 29 0 0 44 Mahogany African 7 0 8 0 8 5 9 5...

Page 13: ...0 0 35 Pine Western white 8 5 9 5 10 5 11 5 12 5 13 5 14 5 15 5 16 5 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 32 0 33 5 34 5 0 42 Primavera 7 0 8 0 9 0 10 0 11 0 12 0 13...

Page 14: ...5 11 5 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 19 5 20 5 21 5 22 5 23 5 24 5 25 5 26 5 27 0 28 0 29 0 0 51 5 5 6 5 7 5 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 15 5 16 5 17 5 18 5 19 5 20 5 21 5 22 0 23...

Page 15: ...nt area contains more moisture than another i e measurements that do not require a high absolute accuracy SG formulas can t be applied to non solid wood species due to the presence of glues and resins...

Page 16: ...igure 1 until the needle rests precisely on the lowest mark on the scale Figure 2 2 Remove the DRY BOX ZERO cap Figure 1 Hold the meter in midair so that the bottom is level and several feet from any...

Page 17: ...ime Wagner Meters recommends purchasing a calibration verification block or returning the unit to the factory for diagnostic checkup and recalibration on the anniversary date of purchase each year the...

Page 18: ...18 NOTES...

Page 19: ...grantee or manufacturer could void the user s authority to operate such equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...