1.
Switch control unit to standby operation.
2.
Unscrew union nut completely (12) and remove air cap (10).
3.
Push ACF 5000 nozzle (11) out of air cap (10) by hand, reverse it and put it into the air
cap (10) with the nozzle tip towards the rear.
Pay attention to the position of the guide surfaces (X).
4.
Insert air cap (10) with integrated ACF5000 nozzle (11) into the union nut (9).
Make sure that the air cap horns (Y) lie in the recess of the nozzle guard.
5.
Screw preassembled union nut (12) to gun (1) and tighten by hand.
6.
Switch on gun without high voltage and fl ush gun.
7.
When the blockage has been fl ushed out, switch control unit back to standby operation.
8.
Unscrew union nut (12) completely.
9.
Remove air cap (10) and push ACF5000 nozzle (11) out of the air cap by hand.
Clean ACF5000 nozzle and insert it in the spraying position into the valve housing.
10. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces (X).
11. Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
12. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
13. Switch control unit to the required operating mode.
7.3.10
ELIMINATE NOZZLE CLOGGING
Summary of Contents for GA 5000EACIC