42
VERSION 05/2018
ORDER NUMBER DOC 2312956
GA 4000ACIC
8.2
MAINTENANCE
8.2.1 MAINTENANCE PERSONNEL
Maintenance work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training.
The following hazards may arise during maintenance work:
– risk to health from inhaling solvent vapors,
– use of unsuitable tools and aids.
An authorized person must ensure that the device is checked for being in a reliable state
after maintenance work is completed.
8.2.2 MAINTENANCE INSTRUCTIONS
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Only repair and replace parts that are listed in the "Spare parts" chapter and that are
assigned to the unit.
Before all work on the device and in the event of work interruptions:
– Switch off the energy and compressed air supply.
– Relieve the pressure from the spray gun and device.
– Secure the spray gun against actuation.
Observe the operating and service manual for all work.
Prior to Maintenance
– Flush and clean the system. Chapter
After maintenance
– Carry out safety checks in accordance with Chapter
.
– Put the system into operation and check for leaks as described in Chapter
.
In accordance with the guideline for liquid ejection devices (DGUV regulation 100-
500 sections 2.29 and 2.36):
- The liquid ejection devices should be checked by an expert (e.g., WAGNER service
technician) for their safe working conditions as required and at minimum every
12 months.
– For shut down devices, the examination can be suspended until the next start-up.
Summary of Contents for GA 4000ACIC-S
Page 1: ...Version 05 2018 GA 4000ACIC S GA 4000ACIC R AirCoat Automatic spray gun II 2G X B_06647...
Page 2: ......
Page 66: ......
Page 67: ......