Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
16 Appendix Device Configuration
68
Order number 2354913 | Edition 10/2022
16 APPENDIX DEVICE CONFIGURATION
EPG
SPRINT X
0
%
100
%
kV
80
60
40
20
100
Tri
Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
µA
P_05015
15
16
1. To access special device configuration, switch the device to [Standby] with the
[Standby] button (15). The yellow [Standby] LED (16) lights up.
EPG
SPRINT X
0
%
100
%
kV
80
60
40
20
100
Tri
Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
µA
P_05016
24
19
31
2. Press [Characteristic slope] button (31) and hold it down.
3. Turn the universal control dial (24) with the other hand until the LED display (19) shows
the number 10. Then release the [Characteristic slope] button (31). The device is now in
configuration mode. The scrolling text [Configuration] is displayed.
EPG
SPRINT X
0
%
100
%
kV
80
60
40
20
100
Tri
Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
µA
P_01747
19
28
30