8
iDentifyinG tiP SiZeS
To identify tip sizes, use the following formula. A “517” tip size will be used in
this example.
The first digit multiplied by two represents the size of the spray pattern when
spraying 12” away from the work surface:
5 x 2 = 10” spray pattern
The second two digits represent the diameter of the orifice on the tip:
17 = .017” orifice
i
Worn spray tips will adversely affect the spray pattern and result in
reduced production, poor finish, and wasted material. Replace worn
tips immediately.
cleanuP
Maintaining a clean gun and spray tip is important to ensure trouble-free
operation. Flush the gun and spray tip after each use and store in a dry
location. Do not leave the gun or any of its parts in water or solvents.
i
Refer to the sprayer’s instruction manual for detailed cleanup
instructions.
Special cleanup instructions for use with flammable solvents:
• Always flush spray gun preferably outside and at least one hose
length from spray pump.
• If collecting flushed solvents in a one gallon metal container,
place it into an empty five gallon container, then flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.