6
k
7
8
P. 11
9
k
10
11
k
0
12
13
EN
15
CLEANUP - CONTINUED
6.
Perform Pressure Relief Procedure (page 7).
7.
Remove the inlet filter. Clean by hand using a soft-bristled brush.
Snap back into place when clean.
Remove the tip guard and spray tip from the cleaning solution.
Clean by hand using a soft bristled brush.
8.
IMPORTANT STEP: Fill the tank with warm, soapy water. Following
steps 5-7 in the “Spraying” section, spray at least one gallon of warm,
soapy water. This will ensure that the spray tip will be completely
clean for the next use.
9.
Perform Pressure Relief Procedure (page 7).
10.
Remove the spray tip assembly.
Repeat step 5 from above, continuing to squeeze the trigger until
fluid comes out clear.
Attention
This pump is liquid-cooled. Do not allow the sprayer
to run without paint or water in the tank.
11.
Turn PRIME/SPRAY knob to PRIME. Turn power OFF.
Replace the spray tip/tip guard assembly.
12.
Grip the spray hose fitting near the spray gun with a wrench. Loosen
and remove the spray hose from the gun.
13.
Place a wrench on the outlet valve to secure it. Using the second
wrench, remove the spray hose.
Hold one end of the spray hose higher than the other and drain
the hose of all cleaning solution into a waste container. Properly
dispose of the cleaning solution.
Move on to the Long Term Storage steps, next page.