25
Control Pro 250 M / 275 M
DE
EN
Interruption of Work
Danger
Be sure to follow the Pressure Relief Procedure when shutting the unit off for any purpose.
This procedure relieves the pressure from the spray hose and the gun.
•
Switch the device off (pressure regulator in position 0) and remove the power plug.
•
Put the spray gun in a plastic bag and seal so that it is air-tight.
•
Wet paint surface in paint container with a little water to prevent a skin from forming.
Taking Out of Operation and Cleaning
Proper cleaning is the prerequisite for problem-free operation of the paint application device. No warranty claims are accepted
in case of improper or no cleaning.
Danger
Do not use flammable materials / cellulose thinner for cleaning purposes.
i
Always clean the device as soon as you have finished operation.
Dried-on coating substance makes cleaning more difficult.
1.
1. Perform Pressure Relief Procedure.
2. Secure the spray gun.
Secure the spray gun.
3. Remove the nozzle holder from the spray gun. (Fig. 19)
4. Put the suction hose and return flow pipe into a container full of water or suitable cleaning solution.
5. Hold the spray gun on the edge of the paint container. (Fig. 20)
Danger
Ground gun with a metal container if flushing with solvent.
6. Unlock the spray gun and pull the trigger.
7. Turn the switch to the SPRAY position and set maximum pressure.
8. Release the trigger again as soon as the cleaning agent comes out.
9. Turn the switch into the PRIME position (vertical).
10. Hold the spray gun on the edge of the cleaning container.
11. Pull the trigger and hold it until only clear liquid comes out.
12. Switch the device off and remove the power plug.
13. Turn the switch into the PRIME position (vertical).
14. Pull the trigger to relieve the pressure.
15. Secure the spray gun.
Secure the spray gun.
16. Separate the spray gun from the paint hose using wrenches (13).
i
If the HEA filter set is being used, remove it and clean it in accordance with the information in the chapter entitled
"HEA Filter Set".
17. Remove the nozzle (1), plain washer (2) and the mounting (3) from the nozzle holder (4) and clean all parts thoroughly.
(Fig.21)
18. Replace the mounting and the plain washer in the nozzle holder.
Screw the nozzle holder onto the gun.
19. Detach the suction hose from the basic unit.
20. Disconnect the return line.
21. Wipe off the exteriors of both hoses.
22. Carefully remove the filter disc (1) from the suction filter. (Fig. 22)
23. Clean the filter disk thoroughly under running water.
24. Remove the high pressure hose from the basic unit with a wrench (17).
i
The steps described below for preserving the pump are particularly important so that the unit can be used again
without any problems the next time it is required.
25. Immerse the inlet valve in a container filled with conservation agent (e.g. household oil). (Fig. 23)
26. Insert the power plug.
27. Hold a cloth in front of the hose connection and switch the device on for approx. 5 seconds. (Fig. 24)
This procedure preserves the pump.